Harman Stove Company PF 100 Furnace User Manual


 
28
PF100
11. Turn Mode Selector to “SERVICE”
This will start the combustion blower and allow the
ESP to control the fire in relation to the Temp Dial set-
ting 1 through 7. Once the fire is well established the
Temp Dial can remain on any number setting desired,or
changed to the “AUTOMATIC”setting. If you change
to “AUTOMATIC” remember to set the Temp Dial to
“ Normal Setting“ for proper Wall Control calibration.
NOTE: When the Switch is set to Manual-Lite in
the “AUTOMATIC” mode, the Wall Control will func-
tion as in Auto-Lite except the fire will not be allowed to
go out. It will only be allowed to go to a minimum burn
rate between the times the Wall Control is calling for
heat.This rate is about 1 pound of fuel per hour.
12. Light The Starting Gel With A Match.
13. Close The Doors
The fire will light and the PF100 will adjust the fire
to proper level according to the temperature dial setting
on the wall control.
14. Return air filter
Check the condition of the return air filter
periodically and replace as needed.
Fig. 59
Solid-fuel burning appliances need to be cleaned
frequently because soot, creosote, and ash may accu-
mulate. If you suspect a chimney/vent pipe fire 1) Call
the fire department. 2) Remove fuel from the burn pot
using the burnpot scraping tool to scrape the pellets into
the ash pan. 3) Remove the ash pan from the unit and
take outside. Do not place ash pan on a combustible
material. 4) Turn off circuit breaker at unit. 5) Do not
use the unit until a qualified person has inspected your
appliance and venting.
Operation