9) Install the plastic bushing over the
outside of the hole.
10) Attach the ground wire to the DC spark
mounting bracket.
11) Attach the DC sparker generator wires to
the DC sparker.
8) Insert both the ground wire and the DC
sparker generator wire through the hole
of the DC spark heat shield.
7) Attach the Piezo ignition wire to the DC
Sparker.
Piezo
Ignitor
13) Attach the heat shield to the DC sparker,
then mount this onto the stove.
Note: We recommend attaching the
DC sparker box to the bottom rear of
the stove (or place this in a convenient
location, away from the heat source).
14) Tie up the loose wire with the wire clip.
Installation of the DC Sparker
for the P90 Units Only:
1) Locate the Piezo Ignitor situated at the
side of valve.
2) Remove the Piezo Ignitor by unscrewing
the nut at the back of the mounting
bracket.
3) Disconnect the ignitor wire from the
Piezo Ignitor and connect it to the DC
Sparker.
Piezo
Ignitor
Ignitor
Wire
Piezo
Ignitor
Ignitor
Wire
DC
Sparker
4) Install the 3/4" nylon plug to cover up the
hole on the mounting bracket.
12) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
NOTE: The battery in the DC Sparker
Box will need to be replaced annually.
Battery
Compartment
INSTALLATION