Hampton Direct H35-NG1 Indoor Fireplace User Manual


 
Hampton
®
H35 Direct Vent Freestanding Gas Stove
15
Horizontal Venting with Two (2) 90
o
Elbows
Option V H + H1
A) 3' Min. 2' Max.
B) 4' Min. 3' Max.
C) 5' Min. 4' Max.
D) 6' Min. 5' Max.
E) 7' Min. 6' Max.
F) 8' Min. 8' Max.
Horizontal Venting with Two (2) 90
o
Elbows
Option H V H + H1
A) 1' Max. 2' Min. 3' Max.
B) 2' Max. 3' Min. 5' Max.
C) 3' Max. 5' Min. 6' Max.
D) 4' Max. 7' Min. 7' Max.
E) 5' Max. 9' Min. 8' Max.
With these options, max.
total pipe length is 30 feet
with min. of 9 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
With these options, maxi-
mum total pipe length is 30
feet with minimum of 8 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
INSTALLATION
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Position" section.
Vent restrictor position A (fully open), refer to the "Vent
Restrcitor Postion" section.
H
H1
V
H1
H
V
Lengths do not include elbow indicated
Lengths do not include elbow indicated