Hamilton Beach SA-HB-40-DB-CERT Water System User Manual


 
16 | Hamilton Beach Owner’s Manual
Hamilton Beach Owner’s Manual | 17
Programming Guide
Level I and II Default Settings
The following table represents preset values programmed into the systems at the factory for both levels I
and II for the model shown. (See Table 7.)
Level I Parameters
Name Description SA-HB-40-DB-CERT SA-HB-48-DB-CERT
P1 Time of day Set in field Set in field
P2 Time of regeneration 2:00 a.m. 2:00 a.m.
P3 Hardness Set in field Set in field
P4 Salt amount 3.0 lbs 4.0 lbs
P5 Capacity 14.1 Kgr @ 3.0 lbs of salt 15.2 Kgr @ 3.6 lbs of salt
Level II Parameters
P6 Refill controller 0.35 gpm 0.35 gpm
P7 Brine draw value 3.0 lbs @ 7 min w/ 5 bump injector
7.5 lbs @ 26 min w/ 4 bump injector
15.0 lbs @ 51 min w/ 4 bump injector
4.0 lbs @ 9 min w/ 5 bump injector
9.0 lbs @ 31 min w/ 4 bump injector
18.0 lbs @ 61 min w/ 4 bump injector
P8 Not used n/a n/a
P9 Backwash time 3.9 min 3.9 min
P10 Slow rinse time 75.5 min @ 3.0 lbs with 5 bump injector
62.0 min @ 7.5 lbs with 4 bump injector
57.0 min @ 15.0 lbs with 4 bump injector
75.5 min @ 3.0 lbs with 5 bump injector
62.0 min @ 7.5 lbs with 4 bump injector
57.0 min @ 15.0 lbs with 4 bump injector
P11 Fast rinse time 3.5 min 3.5 min
P12 Units of measure 0 0
P13 Clock mode 0 0
P14 Calendar override 0 0
P15 Reserve type 0 0
P16 Fixed reserve capacity
or initial average value
n/a n/a
P17 Operation type 1 1
P18 Salt / capacity change
lock out
0 0
P19 Factory defaults 9 9
Table 7: Level I and II programming default settings.