Hamilton Beach SA-HB-40-DB-CERT Water System User Manual


 
10 | Hamilton Beach Owner’s Manual
Hamilton Beach Owner’s Manual | 11
Start Up Rinsing Procedure (con’t)
5. After the ten-minute backwash cycle, manually
advance the control valve to the brine refill
position for ten minutes allowing water to flow
into the brine storage tank. (See Figure 13.)
Once water begins to flow into the tank fill the
brine tank with a minimum of 100 lbs of salt
pellets.
6. After the ten-minute refill time, manually advance
the control valve to the service position. (See
Figure 14.)
7. Plug in the control valve. (See Figure 15.)
8. If it is necessary to extend the length of the
transformer cord, an optional 15 foot (4.6-m)
extension cord is available, (See Figure 16), or the
cord may be spliced as follows:
a. Strip insulation from wire
5
/16 inch (7.87 mm)
from wire end.
b. Insert stripped wire into barrel of connector
and crimp. For best results, crimp twice per
wire as shown in Figure 17 .
Neither splice connections nor extension wire
are supplied. They are available at hardware or
electrical stores.
Figure 16
(AVP-1000907)
Figure 17
Figure 15
Figure 14
Figure 13