Hamilton Beach SA-HB-40-DB-CERT Water System User Manual


 
14 | Hamilton Beach Owner’s Manual
Hamilton Beach Owner’s Manual | 15
Programming Guide
The Level II programming has been programmed by the
manufacturer to the settings in Table 6. The changing of preset
values can be done at this time. Refer to Level II programming
parameters in Table 6 for options.
Note: It is not recommended that homeowners change these values
without checking with local water-treatment professional for details.
Incorrect programming can cause system malfunction and the possible
need for a field service call to reprogram the system. System programming
is not covered under warranty.
To access Level II programming, simultaneously hold down the
up [#] and down [$] arrows. This will allow you to enter Level
II settings P6 through P19. (See Table 6.)
Level II Programming
Level II Programming Parameters
Parameter Description Range Minimum
Increments
Units of
Measure
Notes
P6 Refill controller 1–99 1 gpm .35 gpm, both models
P7 Brine draw value 1–99 1 Minutes 15, both models
P8 Not used n/a n/a n/a n/a
P9 Backwash time 3–30 1 Minutes Skip this parameter to accept the default or enter a value
P10 Slow rinse time 8–125 1 Minutes SA-HB-40-DB-CERT = 67
SA-HB-48-DB-CERT = 80
P11 Fast rinse time 2–19 1 Minutes Skip this parameter to accept the default or enter a value
P12 Units of measure 0–1 1 0 = U.S.
1 = Metric
Skip this parameter to accept the default (U.S.)
P13 Clock mode 0–1 1 0 = 12-hour clock
1 = 24-hour clock
Skip this parameter to accept the default (12-hour)
P14 Calendar override 0–30 1 days 0 = no calendar override
Skip this parameter to accept the default (no override)
P15 Reserve type 0–3 1 0 = variable reserve
P16 Fixed reserve capacity
or initial average
value
0–70 1 percent of
capacity
Description depends on the value entered for P15 (Reserve
type). Skip this parameter to accept the default.
P17 Operation type 0–1 1 0 = Not used
1 = 5-cycle counter current
P18 Salt / capacity change
lock out
0–1 1 0 = none
1 = salt / capacity change locked out
Skip this parameter to accept the default (no lock out)
P19 Factory defaults DO NOT
CHANGE
1 Loads in factory default values. DO NOT CHANGE THIS
PARAMETER.
Table 6: Level II programming parameters.
Level II Programming
Parameters