Stovax PR0919 Stove User Manual


 
23
IGNITION FUNCTIONAL CHECK 1
PILOTWILLNOTLIGHT
Ensurethereisnodebrisaroundthepilotassembly,
(e.g. soot, etc.) which could short the spark, clean the area.
Operatethevalve.
Is there a spark?
Consult User
Instructions and retry.
Check alignment of pilot
burner head, change the
ignition lead.
See Replacing Parts, section 2.
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating and valve. Check thermocouple leads for correct orientation,
condition and connection
Is the gas turned on to the
appliance?
Is the gas pressure correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?
Willthepilotlight
with a match?
No Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
SERVICING INSTRUCTIONS
SERVICING / FAULT FINDING CHARTS
1. SERVICING REQUIREMENTS
This appliance must be serviced at least once a year by a
competent person.
All tests must be carried out in accordance with the current
CORGIrecommendations.
1.1 Before any tests are undertaken on the appliance:
• Conductagassoundnesstestforthepropertytoensure
there are no gas leaks prior to starting work
1.2 • Fullychecktheoperationoftheappliance
Special checks
1.2.1 Cleananylintorflufffromthepilot-payparticular
attention to the aeration holes of the pilot
1.2.2 Clean away any fluff or lint from under the burner
1.2.3 Check the spark gap on the pilot is correct
•Correctanyfaultsfoundduringtheinitialtests
•Recommissiontheapplianceconductingtheusualsafety
checks
1.3 Advise the customer of any remedial action taken.
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY
FAULTS.
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE
PAST:
CHECK THE EMERGENCY SHUT OFF SWITCH
IN THE BOTTOM RIGHT CORNER BY THE DOOR IS
SWITCHED ON, SEE USER SECTION, PAGE 6
Symptom Cause Remedy
3 Short beeps from
control
Batteries low in
appliance
Replace appliance
batteries
No ignition, 5 second
continuous tone (there
may be several short
beeps before)
1.On/Offswitchisin
OFFposition
2. Loose/damaged
wire
1. Move switch to
ONposition
2 Check interrupter
block and wires
No ignition, no tone,
motor turns slightly when
operated
Receiver board
damaged
Replace receiver
No pilot flame and
control continues to
spark
Thermocouple circuit
wired incorrectly
Correct wiring
Pilot lights, control
continues to spark, value
shutsdownafter10-30
seconds
1. No spark at pilot
burner
2. Loose/damaged
wire
1. Rectify spark at
pilot burner
2. Check interrupter
and wires
Electronic Control Valve Fault Analysis