Stovax PR0919 Stove User Manual


 
13
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
1C
AR1673
2.3 TOP FLUE VERTICAL KIT (8524/8524AN)
Vertical from the top of the appliance (See Diagram 1C).
A minimum vertical rise 3m (9’10") to a maximum 10m
(32’10"). The basic kit comprises:
2 x 1m lengths
1 x 1m terminal length
1 x 52mm restrictor
1 x 47mm restrictor
1 x 60mm restrictor
Extralengthsmaybeaddedfromthelistbelow.
2.4 TOP FLUE VERTICAL OFFSET KIT
(8530/8530AN)
Used with kit 8524. A minimum rise of 500mm (19
1
/
2
) is
required to the first bend. See Diagram 1C.
2.5 EXTRA FLUE LENGTHS
All flue components are 150mm diameter (6")
NOMINAL ACTUAL STAINLESS ANTHRACITE
LENGTH LENGTH FINISH FINISH
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
40° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
NOTE: Carefully consider:
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, you must conform to local and
national codes of practice .
3. GAS SUPPLY
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
3.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
3.2 Ensurethegassupplydeliverstherequiredamountofgas
and is in accordance with the rules in force.
3.3 You can use soft copper tubing on the installation and soft
soldered joints outside the appliance and below the fire.
3.4 A factory fitted isolation device is part of the inlet
connection; no further isolation device is required.
3.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
3.6 The gas supply enters through the silicone panel located on
theLEFT-HANDsideoftheouterbox:
• Slitwithasharpknifepriortopassthesupplypipe
through.
3.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
4. VENTILATION