Stovax PR0731 Electric Heater User Manual


 
EMERGENCY SHUT OFF
If the batteries fail during use of the fire:
• MovetheemergencyshutoffswitchtotheOFF(O)
position
This emergency switch is located behind the slotted lower
panel on the underside of the appliance:
3
AR1341
Underside of appliance
Access to switch
• Useaballpointpenornarrowscrewdrivertopushthe
rocker switch to the OFF (O) position, Diagram 4
4
AR1961
Emergency
Shut Off
(This switch is set to be ON (|) during normal operation
and must remain ON)
3. CLEANING THE LINEA
ENSURE THE APPLIANCE IS COLD BEFORE PROCEEDING.
3.1 The outside casing of the Linea should be cleaned using a
damp cloth.
3.2 To clean the glass panel, remove the decorative front as
detailed in the instructions supplied with front.
3.3 Remove the glass panel by unscrewing the nine pozidrive
screws, Diagram 5
6
USER INSTRUCTION
5
AR1339
3.4 Use a damp cloth and warm soapy water. Ensure the glass is
drybeforere-assembling.
3.5 Ensure that the fibreglass seal on the firebox is intact then
hook the location tabs over the hooks on the top of the
firebox. Replace the nine screws working from the top
down, three long ones in the bottom holes. Tighten the
screws evenly.
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
PANEL IS REMOVED OR BROKEN.
4. FLAME FAILURE DEVICE
4.1 This is a safety feature incorporated on this appliance which
automatically switches off the gas supply if the pilot goes
out and fails to heat the thermocouple.
5. RUNNING IN
5.1 The surface coating on the ceramic panel used in your
GAZCO fire will "burn off" during the first few hours of use
producing a harmless and temporary odour. This will
disappear after a short period of use. If the odour persists,
ask your installer for advice.
6. SERVICING
6.1 The fire must be serviced every 12 months by a qualified
Gas Engineer. In all correspondence always quote the
Model number and the Serial number which may be found
on the data badge.
7. VENTILATION
7.1 This appliance requires no additional ventilation.