First Alert FA848C Home Security System User Manual


 
- 23 -
Testing The System
SYSTEM TEST
It is recommended that you test your system once a week using the
following procedure:
NOTE: If your system is monitored, contact your central station before you
perform this test.
1. Turn your security system on.
2. Wait until your exit time is over. Then activate the system by opening a
protected zone (for example: a window or door).
3. Confirm that the alarm sounding device (bell or siren) sounds. If your
system is connected to a central station, the keypad will sound the
ringback tone to confirm that the signal was received.
4. Turn the security system off.
5. Call the central station to tell them you are finished testing.
BATTERY TEST
It is recommended that you test your battery once a month. In order to
test your backup/standby battery, the following procedure should be
followed:
1. Unplug the transformer from the AC outlet by removing the
restraining screw that secures the transformer to the wall. (NOTE:
The screw is not present on the models sold in Canada.)
2. Observe that the AC indicator light on the keypad goes off.
3. Activate your alarm by performing the above SYSTEM TEST.
Remember to contact your central station if your system is monitored.
4. Plug the transformer into the AC outlet and secure with the restraining
screw. (NOTE: the screw is not present on the models sold in Canada.)
The National Fire Protection Association publishes a standard for fire
warning equipment (NFPA publication #72). Further information can be
obtained by contacting: NFPA Public Affairs Dept., Batterymarch Park,
Quincy, MA 02269.
If you have any further questions about the operation of your system,
please contact your alarm company.