Enviro ENVIRO Indoor Fireplace User Manual


 
31
Secondary Installation
QUALIFIED INSTALLERS ONLY
OPTIONAL FAN KIT INSTALLATION:
If the Retreat is installed, the burner and valve assemblies may need to be removed. If the Retreat is not
installed the fan can be installed under the rebox, or through an access hole at the lower rear of the
unit.
WARNING: The electrical grounding instructions must be followed. The fan should be properly
grounded.
Kit Contents:
This kit includes a fan assembly, a wiring harness, a temperature sensor, fan control dial, two (2)
grommets, and two (2) 8-32 x ” bolts.
Please ensure that your fan kit has not been damaged. If so, contact your dealer, distributor, or courier
company before starting this installation.
OPTIONAL FAN KIT INSTALLATION THROUGH FRONT OF RETREAT:
Figure 46. Wiring Diagram For Fan Control.
The optional fan is thermostatically
controlled and it will not operate if the
appliance is cold. A few minutes after
the appliance is lit and the variable speed
control is set at a desired setting, the fan
will automatically turn on. The fan will
automatically turn off a few minutes after
the appliance is shut off.
The replace must be electrically connected
and grounded in accordance with local
codes or, in the absence of local codes,
with the current CSA C22.1 Canadian
Electrical Code Part 1, Safety Standards
For Electrical Installations, or The National
Electrical Code ANSI / NFPA 70 in the US.
CAUTION: When servicing controls, label
all wires prior to disconnection. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
Fan Control
Black
BlackBlack
Long
Black
Short
Black
Electrica