Once you are finished using the pellet appliance for the season, unplug the stove for added electrical protection.
It is very important that the stove be cleaned and serviced as stated above. (See Section Areas of Routine
Inspection)
5
4
3
2
1
ELECTRICAL COMPONENT FUNCTIONS
The following is a list of electrical components and their functions on the ENVIROFIRE EF-IVi pellet stove.
1. CONVECTION FAN CONTROLLER
This controller is responsible for varying the speed of the convection blower. Should the convection blower be set
on low and dial-a-fire set on high, the 160ºF (71ºC) Temp. Sensor will by-pass the fan controller and the fan will
go to full speed. This will cool the stove until control is given back to the fan controller
2. AUGER PULSE LIGHT
This light will flash in conjunction with the pulses to the auger.
3. START-UP SWITCH
When this momentary contact switch is pressed it will initiate the 15-minute start-up cycle including the ignitor.
4. DIAL-A-FIRE (HEAT OUTPUT CONTROL)
This unit is responsible for controlling the timing of the auger motor. When turned clockwise it will cause the OFF
time between auger pulses to shorten, resulting in more heat output and pellet consumption. Turn the knob
counter-clockwise and the reverse will happen. When it is turned fully counter-clockwise past the click, the auger
motor will be off. This component also controls the exhaust blower speed Via the Speed Control Module
5. CONVECTION BLOWER
This blower fan,(mounted on the right side of the stove) draws room air from the back of the stove and passes the
air through the heat exchanger tubes and back into the room. The sealed system keeps the room air separate
from the combustion air. The convection blowers fan controller controls this fan’s speed.