Enviro 1200 Fireplace Insert Stove User Manual


 
29
Installation
The ue collar is removable for installations
into replaces with low openings.
a) Remove the rst two (2) front secondary
air tube and ceramic bafes, if installed
(see CERAMIC BAFFLE INSTALLATION).
b) Unscrew the nut on top of the inside
of the rebox, using a
9
/16” wrench or
socket (see Figure 31). The ue plate
clamp will slide off the hook/clamp.
c) Pull the hook/bolt and the removable
ue collar off the top of the unit.
Figure 32: Attaching removable ue.
Figure 33: Leveling leg.
Nut
Hook/bolt
Flue plate clamp
d) Attach the ue collar to the venting pipe using
sheet metal screws.
e) Push the unit into place while trying to keep the
collar attached to venting close to the opening
on the top of the unit.
f) Using the hook/bolt, grab the ue collar by the
rod through the center and pull it into place (see
Figure 32).
g) Slide the ue plate clamp over the end of the
hook/bolt and screw the nut back on to the
hook/bolt.
h) Re-install ceramic bafes and the rst two (2)
front secondary air tube (see CERAMIC BAFFLE
INSTALLATION).
3. There are two (2) leveling legs (shown in Figure 33),
one on each side, at the back of the unit. Adjust the
legs using a
9
/16” wrench to ensure the unit is stable.
Figure 31: Attaching removable ue.
4. Screw or nail the metal plate provided by the manufacturer to the
inside of the replace.
METAL TAG: “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE
A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED
PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”