Enviro 1200 Fireplace Insert Stove User Manual


 
Specifications
CLEARANCES TO COMBUSTIBLES - 1200 FREESTANDING:
MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*
Single Wall Pipe Double Wall Pipe** Double Wall Pipe
with Heat Shield
(Flat top model only)
Top vent out back
wall with min. 48”
(1220 mm) vertical
rise; double wall
A
From side wall
to side of unit
13”
(330 mm)
13”
(330 mm)
13”
(330 mm)
14”
(356 mm)
B
From rear wall
to back of unit
11”
(279 mm)
10”
(254 mm)
8”
(203 mm)
12”
(305 mm)
C
From adjacent wall
to corner of unit
9”
(229 mm)
8”
(203 mm)
6”
(165 mm)
D
From side wall
to collar
22”
(559 mm)
22”
(559 mm)
22”
(559 mm)
23”
(584 mm)
E
From rear wall
to collar
14”
(356 mm)
13”
(330 mm)
11”
(279 mm)
15”
(381 mm)
F
From adjacent wall
to collar
19”
(483 mm)
18”
(457 mm)
16”
(419 mm)
G
† From front of unit
to edge of hearth pad
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
USA 16” (406 mm)
CND 18” (450 mm)
H
† From side/back of unit
to edge of hearth pad
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
USA 6” (152 mm)
CND 8” (200 mm)
Alcove (48” [1220 mm] Deep)
I Total Width 55” (1397 mm)
J Total Height 78” (1981 mm)
K Top of stove to ceiling 49” (1245 mm)
L Side wall to stove 15” (381 mm)
M Side wall to pipe 24” (610 mm)
N Back wall to unit 12” (305 mm)
O Back wall to pipe 15” (381 mm)
CAUTION: An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed
space, or through a oor, ceiling, wall, or partition, or any combustible construction.
FLOOR PROTECTION: If a stove is installed on a combustible oor, it must have a pedestal attached and be on
a NON-COMBUSTIBLE hearth pad
* ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY.
**DOUBLE WALL:
IN CANADA: Any ULC-S629 listed chimney system with the accompanying listed double wall vent connector.
IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed double wall vent connector.



J








 
I

Table 7: 1200 Freestanding Clearance to Combustibles.
13