Enviro 1200 Fireplace Insert Stove User Manual


 
Installation
MASONRY FIREPLACE INSTALLATION - INSERT:
Unless you are experienced, we recommend installation by your dealer or a
professional installer.
It is recommended that you install the
decorative plates (if purchased) into the
shrouds before installing the unit. Refer to
INSTALLATION OF PODS AND DECORATIVE PLATES -
INSERT.
Install only in a masonry replace at least 25” (635
mm) wide, 22” (560 mm) high and 14” (356 mm)
deep with a good-condition chimney at least 15 ft
(4.6 m) high, both of which have been constructed
in accordance with the building code. Be sure the
replace and chimney are clean and sound without
any cracks or loose mortar. Do not remove any bricks
or mortar from the replace.
If there is a combustible oor in front of the masonry
replace, the replace insert must be 8” (203 mm)
above the combustible oor, and oor protection must
be provided 18” (457 mm) in front of the replace
insert and 8” (203 mm) to each side of the unit.
1. Remove any replace damper or fasten in a
permanent open position.
2. (IN CANADA) The stove is vented with a 6”
stainless steel liner that goes directly to the top of
the chimney and is covered with a rain cap. The
chimney top is sealed with a ashing or steel plate
that supports the weight of the chimney liner. The
installation must conform to the liner’s manufacturer’s
instructions.
This replace must be installed with a continuous
liner of 6” diameter (CANADA ONLY) extending
from the replace insert to the top of the
chimney. The chimney liner must conform to the
class 3 requirements of ULC-S635 Standard for
Lining Systems for Existing Masonry or Factory-
Built Chimneys and Vents, or ULC-S640 Standard
for Lining Systems for New Masonry Chimneys.
(IN U.S.A.)The appliance when installed, must
follow local building codes, in the absence of
local building codes, with the current NFPA 211
Standard for Chimneys, Fireplaces, Vents, and
Solid Fuel-Burning Appliances.
Floor
Protection
Combustible Floor
Masonry Fireplace
18"
(457 mm)
8"
(203 mm)
Rain Cap
Steel Plate or Flashing
Flexible or Rigid 6"
Stainless Steel Liner
Mantel
Top Facing
Damper Removed
or Fastened Open
Sheet Metal Screws
Fastening Collar to
Stainless Steel Liner
Face Plate
Floor Protection
Combustible Floor
Masonry Fireplace
18"
(457 mm)
8"
(203 mm)
Figure 29: Insert Installation into existing replace
with hearth.
Figure 30: Insert Installation into existing replace
without hearth.
28