Enviro 1200 Fireplace Insert Stove User Manual


 
Floor Protection
Combustible Floor
Masonry Fireplace
Rain Cap
Steel Plate or Flashing
Rigid Stainless
Steel Liner
Damper Removed
or Fastened Open
Clean-out tee
Chimney
Support and Clamp
Clean-out
cover
Flexible Stainless
Steel Section
Stainless Steel
Connector Pipe
Listed Liner
Stove pipe must
end higher than liner
Figure 27: Freestanding Installation into existing replace.
installer.
Many venting manufacturers
have listed kits available to
connect a stove to a masonry
replace. Always follow
the vent manufacturer’s
installation instructions.
The existing damper
may have to be removed
to allow installation.
Installation
MASONRY FIREPLACE INSTALLATION - FREESTANDING:
Unless you are experienced, we recommend installation by your dealer or a professional
MOBILE HOME INSTALLATION - FREESTANDING:
SPECIAL REQUIREMENTS: Pedestal models 1200 and 1700 are approved for mobile homes. All
freestanding installation requirements in “
Installation Of A Listed, Factory Built Chimne
y”, must comply
with all local codes that may apply, and the following must be met:
VENTING:
In Canada: Any ULC-S629 listed chimney system with the accompanying double-wall vent connector.
In U.S.A. Any UL-103-HT listed chimney system with the accompanying double-wall vent connector.
Do not connect a listed chimney of one manufacture with a listed double wall connector from another
manufacture.
26