27
Table 13: Examples of Corner Installation Using Clearances From Tables 9 &10 (refer to Figures 23 & 24).
(K) Front of
Hearth Pad to
Corner
(L) Adjacent
Wall
(M) Edge of
Hearth Pad to
Adjacent Wall
(N) Width at
back of Hearth
Pad
(O) Back Corner
Removed -
Adjacent
(P) Back Corner
Removed -
Diagonal
Single
Wall Pipe
1200 Canada 61”
(1558mm)
57”
(1465mm)
29”
(738mm)
30”
(779mm)
4”
(124mm)
7”
(182mm)
USA 59”
(1507mm)
54”
(1393mm)
29”
(738mm)
34”
(881mm)
”
(23mm)
1”
(32mm)
1700 Canada 67”
(1708mm)
61”
(1571mm)
33”
(844mm)
33”
(851mm)
3”
(88mm)
4”
(125mm)
USA 65”
(1657mm)
59”
(1499mm)
33”
(844mm)
36”
(926mm)
0”
(0mm)
0”
(0mm)
Double
Wall Pipe
1200 Canada 59”
(1522mm)
56”
(1439mm)
28”
(713mm)
27”
(707mm)
6”
(160mm)
8”
(227mm)
USA 57”
(1471mm)
53”
(1368mm)
28”
(713mm)
31”
(809mm)
2”
(59mm)
3”
(83mm)
1700 Canada 65”
(1654mm)
60”
(1533mm)
31”
(806mm)
29”
(743mm)
5”
(142mm)
7”
(201mm)
USA 63”
(1603mm)
57”
(1461mm)
31”
(806mm)
33”
(845mm)
1”
(41mm)
2”
(59mm)
Double
Wall Pipe
with Heat
Efciency
Shield 50-
1088 (Flat
top model
only)
1200 Canada 59”
(1522mm)
56”
(1439mm)
28”
(713mm)
27”
(707mm)
6”
(160mm)
8”
(227mm)
USA 55”
(1417mm)
52”
(1330mm)
26”
(675mm)
27”
(701mm)
4”
(133mm)
6”
(160mm)
1700 Canada 64”
(1636mm)
59”
(1520mm)
31”
(794mm)
27”
(707mm)
6”
(160mm)
8”
(227mm)
USA 59”
(1514mm)
55”
(1398mm)
29”
(743mm)
26”
(665mm)
5”
(130mm)
7”
(185mm)
Installation