Table 13: Examples of Corner Installation Using Clearances From Tables 9 &10 (refer to Figures 23 & 24).
(K) Front of
Hearth Pad to
Corner
(L) Adjacent
Wall
(M) Edge of
Hearth Pad to
Adjacent Wall
(N) Width at
back of Hearth
Pad
(O) Back Corner
Removed -
Adjacent
(P) Back Corner
Removed -
Diagonal
Single
Wall Pipe
1200 Canada 61”
(1558mm)
57”
(1465mm)
29”
(738mm)
30”
(779mm)
4”
(124mm)
7”
(182mm)
USA 59”
(1507mm)
54”
(1393mm)
29”
(738mm)
34”
(881mm)
”
(23mm)
1”
(32mm)
1700 Canada 67”
(1708mm)
61”
(1571mm)
33”
(844mm)
33”
(851mm)
3”
(88mm)
4”
(125mm)
USA 65”
(1657mm)
59”
(1499mm)
33”
(844mm)
36”
(926mm)
0”
(0mm)
0”
(0mm)
Double
Wall Pipe
1200 Canada 59”
(1522mm)
56”
(1439mm)
28”
(713mm)
27”
(707mm)
6”
(160mm)
8”
(227mm)
USA 57”
(1471mm)
53”
(1368mm)
28”
(713mm)
31”
(809mm)
2”
(59mm)
3”
(83mm)
1700 Canada 65”
(1654mm)
60”
(1533mm)
31”
(806mm)
29”
(743mm)
5”
(142mm)
7”
(201mm)
USA 63”
(1603mm)
57”
(1461mm)
31”
(806mm)
33”
(845mm)
1”
(41mm)
2”
(59mm)
Double
Wall Pipe
with Heat
Efciency
Shield 50-
1088 (Flat
top model
only)
1200 Canada 59”
(1522mm)
56”
(1439mm)
28”
(713mm)
27”
(707mm)
6”
(160mm)
8”
(227mm)
USA 55”
(1417mm)
52”
(1330mm)
26”
(675mm)
27”
(701mm)
4”
(133mm)
6”
(160mm)
1700 Canada 64”
(1636mm)
59”
(1520mm)
31”
(794mm)
27”
(707mm)
6”
(160mm)
8”
(227mm)
USA 59”
(1514mm)
55”
(1398mm)
29”
(743mm)
26”
(665mm)
5”
(130mm)
7”
(185mm)
Installation