Enviro 1200 Fireplace Freestanding Stove User Manual


 
13
Specifications
CLEARANCES TO COMBUSTIBLES - 1200 INSERT:
A Minimum clearance to an unshielded side wall 10” (254 mm)
B Minimum clearance to an unshielded 8” (203
mm) mantel
21” (533 mm)
C Minimum top facing (protruding ” [19 mm])
clearance
17” (445 mm)
D Minimum side facing (protruding ” [19 mm])
clearance
1” (25 mm)
E † From front of door opening to edge of oor
protection
USA 16” (406 mm)
CND 18” (450 mm)
F From side/back of unit to edge of oor
protection
USA 6” (152 mm)
CND 8” (200 mm)
FLOOR PROTECTION:
If unit is raised 0” - 2” (0mm-51mm); 1” (25mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised 2” - 8” (51mm-203mm); ” (13mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised greater than 8” (203 mm) or more; any non-combustible material can be used.
Table 4: Reduction in (B) Minimum Clearance from 1200 to 8” (203 mm) Mantel.
Type of protection Modied Clearance
A minimum of .013” (0.33mm) sheet metal spaced out 1” (25mm) by non-
combustible spacers.
10” (267 mm)
Ceramic tiles, or eqivalent non-combustible material on non-combustible
supports and spaced out 1” (25mm) by non-combustible spacers.
14” (357 mm)
Ceramic tiles, or eqivalent non-combustible material on non-combustible
supports with a minimum of .013” (0.33mm) sheet metal spaced out 1”
(25mm) by non-combustible spacers.
10” (267 mm)
NOTES:
(1) Mantel protection must have at least 3” (75mm) edge clearance on all sides, except as provided in Note 4.
(2) If an adhesive is used to support non-combustible material, it shall not lose adhesive qualities at temperatures
likely to be encountered and shall not contribute a signicant combustible load.
(3) Heat shield mounting hardware attached to combustible materials must be placed at the lateral extremities of
the shield.
(4) Minimum clearance to unprotected walls and ceilings must be maintained.
Table 5: 1200 Insert Minimum Fireplace Size.
Masonry Zero Clearance
Minimum Depth 13” (343 mm) 14” (279 mm)
Minimum Width at back of replace 22” (568 mm) 23” (584 mm)
Minimum Width at front of replace 27” (686 mm) 27” (692 mm)
Minimum Width at front of replace to include shroud 33” (857 mm) 34” (864 mm)
Minimum Height
19” (489 mm)**
or 19” (502 mm)
20” (508 mm)
** If the masonry lintel height is only 19” (489 mm) to 19” (502 mm) refer to INSTALLATION - MODIFICATIONS FOR
INSTALLATION WITH 19” (489 MM) HIGH LINTEL - INSERT
 
Table 3: 1200 Insert Clearance to Combustibles.