Enviro 1200 Fireplace Freestanding Stove User Manual


 
Installation
HEARTH PROTECTION EXAMPLES:
Table 11: Examples of Hearth Pad Sizing Using Clearances From Tables 9 &10 (refer to Figures 22 & 23).
Canada USA
1200 1700 1200 1700
(A) Minimum Width 40” (1028mm) 36” (926mm)
(B) Minimum Depth
46”
(1168mm)
50”
(1283mm)
42”
(1067mm)
46”
(1181mm)
OPTIONAL - Corner removal
(C) Maximum Front Corners -
Adjacent
8” (314mm) 6” (171mm)
(D) Maximum Back Corners -
Adjacent
6” (160mm) 5” (130mm)
(E) Maximum Front Corners -
Diagonal
12” (314mm) 9” (242mm)
(F) Maximum Back Corners -
Diagonal
8” (227mm) 7” (185mm)
(G) Minimum Width remaining
without corners - Front
23” (583mm) 23” (583mm)
(H) Minimum Width remaining
without corners - Back
27” (707mm) 26” (665mm)
Table 12: Examples of Parallel Installation Using Clearances From Tables 9 &10 (refer to Figure 22).
Model Country
(I) Far Edge of Hearth Pad
to Side Wall - Minimum
(J) Front of Hearth Pad to
Back Wall - Minimum
Single Wall Pipe
1200
Canada 45” (1156mm) 49” (1252mm)
USA 43” (1104mm) 47” (1201mm)
1700
Canada 52” (1333mm) 54” (1391mm)
USA 50” (1283mm) 52” (1340mm)
Double Wall Pipe
1200
Canada 45” (1156mm) 48” (1226mm)
USA 43” (1104mm) 46” (1175mm)
1700
Canada 45” (1156mm) 52” (1340mm)
USA 43” (1104mm) 50” (1290mm)
Double Wall
Pipe with Heat
Efciency Shield
50-1088 (Flat top
model only)
1200
Canada 45” (1156mm) 46” (1175mm)
USA 43” (1104mm) 44” (1125mm)
1700
Canada 45” (1156mm) 50” (1290mm)
USA 43” (1104mm) 47” (1213mm)
Top vent out
back wall
with min. 24”
(610mm) vertical
rise; double wall
1200
Canada 46” (1181mm) 50” (1277mm)
USA 44” (1129mm) 48” (1226mm)
1700
Canada 43” (1104mm) 55” (1417mm)
USA 41” (1053mm) 53” (13466mm)
25