DSCover Satellite Products SCW904x Home Security System User Manual


 
Section 9: Testing & Troubleshooting
49
Trouble [4] Failure to Communicate
Panel fails to communicate one or more
events to central station
Connect a headset to TIP and RING of the control panel. Monitor for
the following conditions:
Continuous dial tone
Reverse TIP and RING
Recorded operator message comes on
Verify correct phone number is programmed
Dial the number programmed using a regular telephone to
determine if a [9] must be dialed or if 800 service is blocked.
Panel does not respond to handshakes.
Verify the format programmed is supported by the central
station.
Panel transmits data multiple times without receiving a
handshake
Verify that the account number and reporting codes are
correctly programmed.
NOTE:
Contact ID and Pulse formats
Program a HEX [A] to transmit a digit [0]
SIA format
Program a digit [0] to transmit a digit [0]
Trouble [5] Zone Fault Press [5] to determine specific zones with a Fault trouble
Hard-wired zone fault condition present.
A short circuit is present on one or more
zones with double end-of-line resistors
enabled
Remove the wire leads from I/O and COM terminals and
measure the resistance of the wire leads.
Connect a 5.6K resistor (Green, Blue, Red) across the I/O and
COM terminals. Verify the trouble condition clears.
One or more wireless devices have not
checked in within the programmed time
Perform a Module Placement Test – Program Section [904] and
verify the wireless device is in a good location.
If bad test results occur, test the wireless device in another
location
If the wireless device now tests good, the original mounting
location is bad
If the wireless device continues to give bad test results
replace the wireless device.
Trouble [6] Zone Tamper Press [6] to determine specific zones with a Tamper trouble
An open circuit is present on one or
more zones with double end-of-line
resistors enabled
Remove the wire leads from I/O and COM terminals and
measure the resistance of the wire leads.
Connect a 5.6K resistor (Green, Blue, Red) across the I/O and
COM terminals.
Verify the trouble condition clears.
A tamper condition is present on one or
more wireless devices
Ensure device cover is secure
Ensure device is correctly mounted for wall tamper operation
Violate, then restore the tamper:
If tamper condition persists then replace wireless device
Trouble [7] Wireless Device Low Battery Press [7] to scroll through specific devices with a Low Battery Trouble
1st press
– Wireless Zones
2nd press
– Wireless Keys
One or more wireless devices has a low
battery
NOTE: The event will not be logged to
the event buffer until the wireless device
low battery delay time expires
Program Section [377] Opt 9
Replace Battery
Verify zone operation
Verify that tamper and low battery condition is cleared and
reported
NOTE: Replacing batteries will cause a tamper. Replacing cover will
restore the tamper causing the associated reporting codes to be sent
to the Central Station.
Trouble [8] Loss of Clock/Date
The main panel internal clock is not set
To program the time and date:
Enter [][6][Master Code] then Press [1]
Enter the time and date (in military) using the following format:
HH:MM MM/DD/YY
Example.
For 6:00 pm, Nov. 30, 2007
Enter: [18] [00] [11] [30] [07]
WWW.DIYALARMFORUM.COM