DSCover Satellite Products SCW904x Home Security System User Manual


 
7.2 Programming Worksheets
19
[030] Zone Loop Response Options
[101]-[134] Zone Attributes (Options 10-13 are reserved for Future Use).
Zone Attribute Defaults
Opt Def. ON OFF
1
Zone 33 is Fast Loop Response
Zone 33 is Normal Loop Response
2
Zone 34 is Fast Loop Response
Zone 34 is Normal Loop Response
3-8
Future Use
Attribute: 1 2 3 4 5 6 7 8 9 14 15 16
ON Audible Steady Chime Bypass Force* Swing Tx. Delay Cross Zn
2-way Audio
NC SEOL DEOL
OFF Silent Pulsed No No No No No No No Loops
Zone Type:
00 Null Zone OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
01 Delay 1 ON ON ON ON OFF ON OFF OFF ON OFF ON OFF
02 Delay 2 ON ON ON ON OFF ON OFF OFF ON OFF ON OFF
03 Instant ON ON ON ON OFF ON OFF OFF ON OFF ON OFF
04 Interior ON ON OFF ON OFF ON OFF OFF ON OFF ON OFF
05 Interior Stay/Away ON ON OFF ON ON ON OFF OFF ON OFF ON OFF
06 Delayed Stay/Away ON ON OFF ON ON ON OFF OFF ON OFF ON OFF
07 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
08 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
09 24hr Superv. (Hardwired) OFF ON OFF OFF ON OFF OFF OFF OFF OFF ON OFF
10 24hr Superv. Buzzer OFF ON OFF ON OFF OFF OFF OFF ON OFF ON OFF
11 24hr Burglary ON ON OFF ON OFF OFF OFF OFF ON OFF ON OFF
12 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
13 24hr Gas ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF
14 24hr Heat ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
15 24hr Medical ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF
16 24hr Panic ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF
17 24hr Emergency ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF
18 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
19 24hr Water ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF
20 24hr Freeze ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF
21 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
22 Momentary Keyswitch Arm
OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON OFF
23 Maintained Keyswitch (Hardwired)
OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON OFF
24 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
25 Interior Delay ON ON OFF ON OFF OFF OFF OFF ON OFF ON OFF
26 24hr Non-alarm OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON OFF
27-31 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
32 Instant Stay/Away ON ON OFF ON OFF ON OFF OFF ON OFF ON OFF
33 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
34 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
35 Future Use OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
36 24hr Non-latching Tamper OFF ON OFF OFF OFF ON OFF OFF OFF OFF ON OFF
37 Night Zone ON ON OFF ON ON ON OFF OFF ON OFF ON OFF
87 Delay 24hr Fire (Wireless) ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
88 Stand. 24hr Fire (Wireless) ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
89 Auto-verified Fire (Wireless) ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
* For UL installations, do not change attribute 5 (Force Arming) from the default setting.
For CP-01 installations:
Option 6 (Swinger) is defaulted ON for zone definitions 09-11, 13-17, 19,20
Option 7 (Tx Delay) is defaulted ON for zone definitions 01-06, 09-11, 13-17, 19,20,25,32,36,37