DSCover Satellite Products SCW904x Home Security System User Manual


 
Self Contained Wireless Alarm System v1.0
32
[074] First Keypad Options
[075] Second Keypad Options
[076] Third Keypad Options
[077] Programmed LCD Message
[078] Programmed LCD Message Duration
[201]-[234] Door Chime Options for Zones 1 - 34
[996] Reset Programmable Labels to Factory Defaults
Opt Def. ON OFF
1
Future Use
2
[A] Key Enabled
[A] Key Disabled
3
[P] Key Enabled
[P] Key Disabled
4
Quick Arm Prompt ON
Quick Arm Prompt OFF
5
Quick Exit Prompt ON
Quick Exit Prompt OFF
6
Bypass Options Prompt ON
Bypass Options Prompt OFF
7
User Initiated Call-up Prompt ON
User Initiated Call-up Prompt OFF
8
Hold [P]anic Key Prompt ON
Hold [P]anic Key Prompt OFF
Opt Def. ON OFF
1
Local Clock Display Enabled
Local Clock Display Disabled
2
Local Clock Displays 24 Hr. Time
Local Clock Displays AM/PM
3
Auto Alarm Scroll Enabled
Auto Alarm Scroll Disabled
4
Language Selection Accessible From Any Menu
Language Selection Accessible From Installer Only
5
Power LED Enabled
Power LED Disabled
6
Power LED indicates AC Present
Power LED indicates AC Absent
7
Alarms are Displayed while Armed
Alarms are NOT Displayed while Armed
8
Auto Scroll Open Zones Enabled
Auto Scroll Open Zones Disabled
Opt Def. ON OFF
1
Chime Enabled for Zone Openings
Chime Disabled for Zone Openings
2
Chime Enabled for Zone Closings
Chime Disabled for Zone Closings
3-8
Future Use
|____|____|____|____|____|____|____|____|____|____|____|____|____|____|____|____|
|____|____|____|____|____|____|____|____|____|____|____|____|____|____|____|____|
|____|____|____| Default 003 (Valid entries are 000-255, 000=Unlimited Message Display)
Opt Def. ON OFF
1
6 Beeps
Disabled
2
Bing Bing Sound
Disabled
3
Ding Dong Sound
Disabled
4
Alarm Tone
Disabled
5-8
Future Use
WWW.DIYALARMFORUM.COM