Section 3: Template Programming
9
Installer Lead-in/Lead-out and DLS Lead-in/Lead-out
Digit 4 indicates/selects 1 of the 3 following DLS Connections
After the 4th digit is entered you will be prompted to enter the following Data.
Refer to Section 8 for additional programming functions.
Users OPENINGS, Residential Dial Reporting codes Section
1-8 1112131415161718[342]
9-16 21 22 23 24 25 26 27 28 [342]
40 98 FF XX XX XX XX XX XX [344]
Enable Opening/Closings call directions for Phone 2
FF=Communicates in Automatic Mode, XX=Not Used
[367]Opt 2 ON
DLS Lead In
Sect [347] Opt 4
DLS Lead Out
Sect [347] Opt 5
Installer Lead Out
Sect [347] Opt 11
Installer Lead In
Sect [347] Opt 12
Disabled for all Template Options except Option 8
Option
Double Call
Sect [401] Opt 1
Call Back
Sect [401] Opt 3
#Rings
Sect [406] Opt 3
1

0
2

8
3

8
Entry 5 Central Station Telephone Number
- Enter 32 Character Telephone number - See Section [301] for details.
Entry 6 Central Station Account Code
- Enter the 6-digit code - See Section [310] for details.
Entry 7 DLS Access Code
- Enter the 6-digit code - See Section [403] for details.
Entry 8 Entry Delay1, Exit Delay
- Enter Entry Delay1, Exit Delay - See Section [005] entries [1], [3] for details.
Entry 9 Installer Code
- Enter a 4 or 6-digit entry depending on setting of Section [701] Opt 5 - See Section [006] for details.