Drolet ECO-65 Stove User Manual


 
3.3. VENTING SYSTEM MAINTENANCE
REGULARLY EXAMINE THE FLUE PIPES, THE JOINTS, AND THE SEALING TRIMS TO ENSURE
THAT THE SMOKE AND THE COMBUSTION GASES ARE NOT TRANSPORTED INTO THE AIR
DUCTING SYSTEM.
The most efficient method to sweep the venting system is by using a 4-inch pellet brush. Brush downwards so
ash, soot and creosote residues will come off the inner surface and fall at the bottom of the venting system
where they can be removed easily. The chimney must be in good condition and kept clean.
If a significant layer of creosote has accumulated (3mm / 1/8” or more), it must be removed immediately
to eliminate the risk of a chimney fire.
3.3.1. Dealing with a Chimney Fire
Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow
these steps:
1. Immediately turn off the stove;
2. Alert your family of the possible danger;
3. If you require assistance, alert your fire department;
4. If possible, use a dry chemical fire extinguisher, baking soda or sand to control the fire. Do not use
water as it may cause a dangerous steam explosion;
FIGURE 21
Clean out trap and Pressure tap
location