Drolet ECO-65 Stove User Manual


 
2.5. LIGHTING PROCEDURE
a. Fill hopper and clean burn pot.
b. Press “MODE” button to select the desired setting “MANUAL” or “THERMOSTAT”
c. Adjust feed rate to desired setting by pressing “-” or “+” button.
If fire doesn‟t start in 35 minutes, a warning code will appear. Refer to troubleshooting section for more
details.
2.6. UNIT CONTROLS (See Figure 16)
The blowers and automatic fuel supply are controlled from a panel on the right-hand side of the ECO-65. The
control panel functions are as follows.
a. MODE SWITCH
When the mode switch is pressed, you will be able
to choose the Manual or the Thermostat mode, or
to turn off the appliance. If the Manual mode is
selected, the stove will automatically ignite. At this
time, the heat level must be selected manually to
adjust the stove‟s heat output to the desired level.
If the thermostat mode is selected, the stove will
automatically modulate between the lowest heat
level and the heat level selected to keep the room
temperature at the thermostat‟s setting. If the set
room temperature is achieved while the stove has
been running at the lowest heat level for more
than 45 minutes, the unit will automatically shut off
and will start another ignition cycle only when the
thermostat calls for heat again. No fire starter is
necessary to ignite the unit. The auger will feed
fuel and the electronic igniter will start. If the unit
doesn‟t ignite within 12 minutes, the stove will start
another ignition cycle. If ignition fails a second
time, a warning message will appear on the
control panel.
The Heat Level may be selected during the
ignition cycle. However, the unit will only feed fuel
at the desired heat level setting when the heat
sensor located into the stove will receive a signal
indicating that the unit has been fully ignited. This
may take anywhere between 10 and 15 minutes.
b. FUEL FEED SWITCH
When the “Fuel Feed” button is pushed the stove
will feed pellets continuously into the burn pot
during 1 minute.
CAUTION: THIS FUNCTION CAN ONLY BE
OPERATED WHEN THE STOVE IS IN “OFF”
POSITION. THE FUEL FEED SWITCH IS USED TO
PRIME THE AUGER WHEN AUGER IS EMPTY.
FIGURE 17
PC board