Desa VDDVF36PN/PP Indoor Fireplace User Manual


 
106918-01B
For more information, visit www.desatech.com
For more information, visit www.desatech.com
5
5
PRE-INSTALLATION PREPARATION
Clearances
Mantel Clearances
Framing
CLEARANCES
Minimum clearances to combustibles are:
Back and Sides of Surround: .................................. 0" min.
Vent Surfaces:............................................1" (2.5cm) min.
Ceiling to Opening: ..................................36" (91cm) min.
Floor: ...................................................................... 0" min.
Wall to Front of Glass: .............................36" (91cm) min.
Perpendicular Wall to Opening of Unit: .......2" (5cm) min.
Top Spacer: ............................................................. 0" min.
CAUTION: Do not block required air spaces with
insulation or any other material. Do not obstruct the
effective opening of the appliance with any type of
facing material.
PRE-INSTALLATION
PREPARATION
Figure 4 - Minimum Clearances (Peninsula Shown)
Figure 5 - Minimum Clearances (See-thru Shown)
CEILING
WALL
36"
(91cm)
Min.
36"
(91cm)
Min.
0" Floor
0"
36"
(91cm)
2" (5cm)
Wall In Front Of Glass
36" (91cm) Min.
Perpendicular
Wall 2" (5cm)
Min. From Opening
Right Side
Surround
(0" Min.)
Left Side
Surround
(0" Min.)
TOP VIEW
Combustible
Material
Drywall
2 x 4 Stud
Minimum 1"(2.5cm)
Clearance from Side
(Only for See-thru)
MANTEL CLEARANCES
Woodwork, such as wood trims, mantels, and other combustible
materials projecting no more than 1
1
/2 inches (3.8cm) shall not be
placed within 7 inches (17.8cm) from the opening of the unit.
Combustible material above and projecting more than 1
1
/2 inches
(3.8cm) from the appliance’s face must not be placed less than 15
inches (38.1cm) from the louver opening (see Figure 6).
Figure 6 - Mantel Clearances for Peninsula and See-thru
Fireplaces (Peninsula Shown)
12"
(30.5cm)
Min.
21"
(53.3cm)
Min.
15"
(38.1cm)
Min.
4"
(10.2cm)
Min.
7" (17.8cm)
Min.
1
1
/2" (3.8cm)
Min.
UNIT
Spacer
2 x 4
Combustible
Material May
Be Used
Drywall (Gypsum
Board, Sheetrock, Etc.)
Safe Zone for Projection
of Combustible Material
Top of Louver
Opening
FRAMING
Once the final location has been determined, observing height
clearances for vent termination, you may construct framing using
dimensions shown in Figure 7 and Figures 8 and 9, page 6,
depending on your installation.
If the appliance is to be installed directly on carpeting, tile (other
than ceramic), or any combustible material other than wood floor-
ing, the appliance must be installed on a metal or wood panel
extending the full width and depth of the appliance. There are three
holes on each side of the bottom of the unit where screws can be used
to secure the unit to the floor.
Figure 7 - Rough Opening for Installing Peninsula Fireplace
39
3
/
4
"
(101cm)
Min.
40
1
/
2
"
(102.9cm
)
23
5
/
8
"
(60cm
)