Desa VDDVF36PN/PP Indoor Fireplace User Manual


 
106918-01B
For more information, visit www.desatech.com
For more information, visit www.desatech.com
28
ACCESSORIES
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA International’s Technical Ser-
vice Department at 1-866-672-6040. When calling, please have your
model and serial numbers ready.
You can also visit DESA International’s Technical Services web
site at www.desatech.com.
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burner will have delayed ignition
fireplace will not produce specified heat
propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local
gas supplier.
RECEIVER AND HAND-HELD ON/OFF
REMOTE CONTROL KIT - GHRC SERIES
For all models. Allows the gas log heater to be turned on and off by
using a hand-held remote control.
BLOWER KIT - DAVDBK (02261)
For all models. Increases air circulation to maximize heat distribution.
LOUVER KIT
Brass - VFLP36 (01628)
END LOUVER KIT
(Peninsula Only)
Brass - VELP20 (01638)
WIRING DIAGRAM
ACCESSORIES
SERVICE HINTS
TECHNICAL SERVICE
Thermocouple
Incoming
Main
Gas
Supply
Piezo Ignitor
Control
Valve
Variable Speed
Control
* Remote
Control
Electrical Rating:
120v, 60Hz, 0.7A
Blower
* Use Extension Cord (Included With Kit)
Pilot
TH
TP
TPTH
Thermopile
Piezo Ignitor
Do Not
Connect
To 120V
N.O.SW
(Wall Switch
Supplied)
Pilot
Gas Line
Wireway
GND
BLK
WHT
GRN
Incoming
120V AC
(Fuse Box
or
Breaker)
Connectors
(Not Supplied)
Field Wire
N.O.SW
(Wall Switch
Not Supplied)
WIRING DIAGRAM