www.desatech.com
117437-01D8
Figure 9 - Clearances for Combustible
Mantels
Figure 8 - Side Clearances for
Combustible Mantels
PRE-INSTALLATION PREPARATION
Continued
1
1
/
2
"
(3.8 cm)
3
1
/
2
"
(8.9
cm)
Outer
Surround
Combustible
Material May
Be Used
Perpendicular
Side Wall
5
1
/
4
"
(13.3 cm)
1
3
/
4
"
(4.4 cm)
To Fireplace
Opening
10" (25.4 cm)
33°
Safe
Zone
Ref. Mantel Depth Ref.
Mantel from
Top of Louver
Opening
1 16" (40.6 cm) A 18" (45.7 cm)
2 14" (35.6 cm) B 16" (40.6 cm)
3 12" (30.5 cm) C 14" (35.6 cm)
4 10" (25.4 cm) D 12" (30.5 cm)
5 8" (20.3 cm) E 10" (25.4 cm)
6 4" (10.2 cm) F 8" (20.3 cm)
7 2" (5.1 cm) G 6" (15.2 cm)
C
B
A
D
E
F
G
Top of Louver
Opening
3
2
1
4
5
6
7
Stud Wall
4" B-Vent
Flue Pipe
2 x 4 Header
at 1" Min.
Clearance
MANTEL CLEARANCES
various heights above top of louver opening.
distances from various mantel components in
WARNING: When nishing
appliance do not overlap com-
bustible materials onto the black
front face. Brick, tile or other
noncombustible materials may be
applied to the face provided that
any replace openings are not
blocked and gaps in the material
used and the face are sealed with
a noncombustible caulking.