Desa CB36P Gas Heater User Manual


 
www.desatech.com
117437-01D 21
OPERATING FIREPLACE
Continued
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Re-
placing Glass Door
2. Follow steps 1 through 8 under Lighting
Instructions
3. Press gas control knob and light pilot with
match.
4.
Keep gas control knob pressed in for 30
seconds after lighting pilot. After 30 sec-
  
steps 10 through 11 under Lighting Instruc-
tions
5. Replace glass door (see Removing/Re-
placing Glass Door
ELECTRONIC IGNITION
SySTEM
LIGHTING
INSTRUCTIONS
     
page 20.
 -
place.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
5. Turn equipment shutoff valve clockwise
to the OFF position (see Figure
34). Do not force.
 



smell gas go to the next step.
7. Turn equipment shutoff valve counter-
clockwise to the ON position. Do
not force.
8. Close lower louver panel.
 
10. Turn wall switch to the ON position.
Figure 35 - Pilot
Pilot
Burner
Ignitor
Sensor
Rod
Figure 34 - Turning Equipment Shutoff
Valve to the OFF Position
11. Visually locate pilot. Ignitor should begin
to spark and main burner should ignite


 
before supply gas can reach pilot and
main burner.
• If appliance will not stay lit after several
To Turn
Off Gas To Appliance  
service technician or gas supplier.
NOTICE: During initial operation
of a new heater, the burning of
residues from the manufacturing
process of the rebox and logs
will produce a paper-burning smell
and orange ames. Open a window
for the rst few hours of operation
to adequately vent this smell.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off wall switch.
2. Turn off all electric power to appliance if
service is to be performed.
3. Open lower louver panel.
4. Turn equipment shutoff valve clockwise
to OFF. Do not force.
5. Close lower louver panel.
OPTIONAL WIRELESS
REMOTE OPERATION
Note: The WRC receiver and hand-held
remote control kit must be purchased sepa-
rately (see Accessories, page 31). Follow
installation instructions included with the
remote control.
1. Turn equipment shutoff valve to ON posi-
tion. You can now turn burner on and off
with hand-held remote unit.