Dell C61 Gas Heater User Manual


 
IPMI OEM Command List | 68
Entity 3 1 Specifies the physical
controller the image is
associated with.
0: BMC
1: SYSTEM (BIOS)
2: PDB
3: FCB
R

Product Info 4 1..64 A text string that identifies
the product.
"Dell DCS Remote
Management Controller"
(default)
R

Firmware Version 5 1..16 A string containing the
BMC firmware version.
The firmware version is
reading from IPMI Get
Device ID command. The
format of BMC FW
Version string is
"<major>.<minor>", where
major is one character and
minor is two characters.
R

Branch 6 1..16 A string containing the
firmware branch
information.
R

Build Information 7 1..16 A string containing the
firmware build number
information. The string
format is YYMMDD.
R

User Default Setting 8 1 This attribute enables user
to customize various BMC
settings and store as user
default. It also allows user
to erase current settings and
restore back to previously
set user default settings.
User default settings
include all write-able
settings in Extended
Configuration Parameters,
IPMI User Account
W