Dell C61 Gas Heater User Manual


 
Sensors Threshold | 38
Sensor
Number
Sensor
Name
The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
0x98 0x96 0x92 0x7D 0x7F 0x84
19h PS 1.1V
Actual_Reading (Volts) = Raw_Data x 0.0087
0xFF 0xFF 0xFF 0x00 0x00 0x00
51h
VCORE
1
Actual_Reading (Volts) = Raw_Data x 0.0083
0x64 0x62 0x5F 0x00 0x00 0x00
52h
VCORE
2
Actual_Reading (Volts) = Raw_Data x 0.0116
0x70 0x6E 0x6B 0x00 0x00 0x00
53h
VCORE
3
Actual_Reading (Volts) = Raw_Data x 0.0083
0x64 0x62 0x5F 0x00 0x00 0x00
54h
VCORE
4
Actual_Reading (Volts) = Raw_Data x 0.0116
0x70 0x6E 0x6B 0x00 0x00 0x00
Temperature
21h
MLB
TEMP
1
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
22h
MLB
TEMP
2
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
23h
MLB
TEMP
3
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
24h
MLB
TEMP
4
Actual_Reading (degrees C) = Raw_Data
0x55 0x50 0x4B 0x00 0x00 0x00
25h
NB1_T
EMP
Actual_Reading (degrees C) = Raw_Data
0x77 0x75 0x73 0x00 0x00 0x00
26h
NB2_T
EMP
Actual_Reading (degrees C) = Raw_Data
0x77 0x75 0x73 0x00 0x00 0x00