Dell C61 Gas Heater User Manual


 
Sensors Threshold | 37
3
Sensors Threshold
Table Error! No text of specified style in document.-8. Sensors Threshold
Sensor
Number
Sensor
Name
The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
Fan
01h
FCB
FAN1
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
02h
FCB
FAN2
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
03h
FCB
FAN3
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
04h
FCB
FAN4
Actual_Reading (RPM) = Raw_Data x 100
0xFF 0xFF 0xFF 0x00 0x0F 0x00
V
oltage
14h PS 12V
Actual_Reading (Volts) = Raw_Data x 0.062
0xD8 0xD4 0xCF 0xAB 0xAF 0xB4
15h PS 5V
Actual_Reading (Volts) = Raw_Data x 0.026
0xD7 0xD3 0xCD 0xA9 0xAE 0xB3
16h
Standby
3.3V
Actual_Reading (Volts) = Raw_Data x 0.0172
0xD6 0xD3 0xCD 0xA9 0xAD 0xB3
17h PS 3.3V
Actual_Reading (Volts) = Raw_Data x 0.026
0xFF 0xFF 0xFF 0x00 0x00 0x00
18h PS 1.2V Actual_Reading (Volts) = Raw_Data x 0.0087