Included with this blower system as:
a) Two multi-speed blowers rated at 120 volts, 60Hz, 6.5 amperes, and 525 CFM each.
b) Two ducts for mounting blowers to fireplace.
c) Two blower grille covers with rheostat fan speed controls pre-mounted.
d) 10 wire nuts.
e) One Wall mountable thermostat.
f) One air discharge snap disc mounted & wired in front air discharge duct (right side.)
g) Electrical box, right side to connect snap disk to thermostat connection.
FIGURE 14 shows the proper components and wiring procedure for connecting the blower
system. Follow all local electrical and safety codes as well as the National Electrical Code when
installing electrical wiring.
FIGURE 14: ELECTRICAL SYSTEM
Version 7.1
21
A certified electrician should provide the electrical circuit and connect the fireplace furnace to the
electrical supply. The blower systems and the Smart Fireplace Furnace must be electrically
grounded. Grounding can be accomplished with a grounded metal-clad raceway system or by
using a separate ground wire connected to the bare metal of the blower frame and fireplace box or
other suitable means. Disconnect all power sources from the fireplace before working on or near
the blower motor system or its components. Be careful when touching the exterior of an
operating blower motor. Modern motors are built to operate at high temperatures that may be hot
enough to cause pain or personal injury. Be careful around the moving parts of the blower motor
system. When installing the blower system ensure that the power cables and blower leads remain