Conair UGE014/0999 Water System User Manual


 
Water/Spray Tanks UGE014/0999
5-4 MAINTENANCE
Normal operation of the WT/ST Tank produces many wet sur-
faces. If you have the optional recirculation system, we rec-
ommend that you carefully check all electrical wires for signs
of damage that could result in a serious shock.
Stop the WT/ST tank. Press the REC STOP button
and lockout the main power source.
Open the electrical enclosure. A safety device
prevents you from opening the door unless the power
is shut down.
Inspect the wires and connections. Look for
loose wires, burned contacts, and signs of over-heated
wires. Have a qualified electrician make any repairs
or replacements necessary.
Inspect the exterior power cords. Carefully
check the power cords from the electrical enclosure
to the pumps. Cords should not be crimped, exposed
or rubbing against the frame. Also check the power cord
to the machine. If the main power cord runs along the
floor, make sure it is not positioned where it could be run
over and cut by wheels or casters.
CHECKING
ELECTRICAL
CONNECTIONS
WARNING: High voltage
This equipment is powered by three-
phase main voltage. Always disconnect
and lock out the main power source
before opening the unit or servicing.
1
2
3
4