Conair UGE014/0999 Water System User Manual


 
Water/Spray Tanks UGE014/0999
3-6 INSTALLATION
The standard WT.ST tanks are designed for use with city,
tower or chilled water supplies. You may choose to treat the
water to prevent algae build-up.
Connect the main water supply to the 1
1
/2-inch
NPT fitting on the tank.
Connect the compressed air supply to the fitting
on the tank air wipe compartment.
CONNECTING
THE
WATER AND
AIR SUPPLIES
WARNING:
Do not use deionized water, brine
or other corrosive water mixtures for the main water
supply unless your tank has been specially designed
for such mixtures. Consult a water treatment special-
ist for the best way to prevent algae build-up without
damaging the equipment.
1
2
You can connect a chiller to the tanks optional heat exchang-
er to remove heat from the extrudate more efficiently.
Typically, the tank comes with the 3/4 inch lines of the stan-
dard tube and shell heater plumbed to the tanks water mani-
fold. The 1
1
/
2
inch inlet and outlet of the heat exchanger can
be used for the chiller.
For maximum water flow:
Connect the chiller To Process and From Process lines to
the largest NPT fittings in the shell of the heat exchanger.
For maximum cooling efficiency:
Connect the chiller To Process and From Process lines to
the smallest NPT tube ends of the heat exchanger.
TIP: If you have a water
supply with high mineral
content, connect the chiller
to the tube ends of the
heat exchanger.
CONNECTING A
CHILLER
From chiller
To chiller
To water manifold
From water
pump
From chiller
To chiller
To water manifold
From water pump