Conair UGE014/0999 Water System User Manual


 
UGE014/0999 Water/Spray Tanks
INSTALLATION 3-7
TESTING THE
INSTALLATION
Adjust the standpipe for the water level you
want to maintain.
Turn water supply on and fill the tank.
Water fills the tank to the water level you set.
If you have a spray tank, water should enter the tank
through the spray bars.
Excess water flows through the drain lines.
If you have the optional recirculation system:
Turn water pump on.
Press the REC START button.
The pump draws water through the heat exchanger and
into the upper tank.
Check the pump for proper rotation. The pump
rotation must match the direction indicated on the rotation
sticker on top of the pump.
If the pump rotation is incorrect, turn off the pump and
disconnect power. Swap any two of the three power source
wires on the terminal block in the electrical enclosure.
WARNING: Voltage Hazard
Always disconnect and lock out the main power
sources before making electrical adjustments.
Electrical adjustments should be made only by
qualified personnel.
WARNING: If a pump rotates in the wrong
direction for more than a very short time, dam-
age will occur.
!