Conair UGE014/0999 Water System User Manual


 
SPECIFICATIONS
Water/Spray Tanks UGE014/0999
2-4 DESCRIPTION
MODEL WT104 WT/ST105* WT/ST107
TANK STYLE 104-12--2 104-16-2 104-21-2 WT105-12-2 105-16-2 105-21-2 107-16-2 107-21-2
Performance characteristics
Tube/profile diameter in. {cm} up to 2 {5.1} up to 4.5 {11.4} up to 6.625 {16.8}
Tank cross section in. {cm} 8 x 8 {20.3 x 20.3} 12 x 12 {30.5 x 30.5} 14 x 14 {35.6 x 35.6}
Water flow gpm {liters/sec} 35 {2.7} 35 {2.7} 50 {3.8}
Dimensions inches {cm}
A - Overall height 52 {132} 52 {132} 52 {132} 53 {135} 53 {135} 53 {135} 54 {137} 54 {137}
B - Height to centerline
42 {107} 42 {1067} 42 {1067} 42 {1067} 42 {1067} 42 {1067} 42 {1067} 42 {1067}
C - Overall length 156 {396} 204 {518} 264 {671} 156 {396} 204 {518} 264 {671} 204 {518} 264 {671}
D - Tank length
144 {366} 192 {468} 252 {640} 144 {366} 192 {468} 252 {640} 192 {468} 252 {640}
E - Overall width 26.5 {67} 26.5 {67} 26.5 {67} 26.5 {67} 26.5 {67} 26.5 {67} 26.5 {67} 26.5 {67}
Weight lbs {kg}
Shipping 950 {430} 1050 {476} 1150 {522} 1200 {544} 1300 {590} 1400 {635} 1600 {726} 1700 {816}
Water requirements 80 gpm @ 60-70 psi {6.1 liters/sec @ 4.8-5.5 bars}; main supply line 1.5 in. NPT fitting
Compressed air requirements maximum consumption 5 SCFM @ 80 psi {0.38 liters/sec @ 6.1 bars}
SPECIFICATION NOTES:
These tables define stan-
dard configurations only.
Specifications can
change without notice.
ST models come with
spray bars.
* 12-foot tank available
as WT water tank only.
† Centerline height is
adjustable ± 2 inches.
MODEL WT/ST109 ST114 ST118
TANK STYLE 109-16-2 109-21-2 114-16-2 114-21-2 118-16-2 118-21-2
Performance characteristics
Tube/profile diameter in. {cm} up to 8.5 {21.6} up to 13 {33.0} up to 18 {16.8}
Tank cross section in. {cm} 16 x 16 {40.6 x 40.6} 22 x 22 {55.9 x 55.9} 26 x 26 {66 x 66}
Water supply flow gpm {liters/sec} 60 {4.5} 60 {4.5} 60 {4.5}
Dimensions inches {cm}
A - Overall height 55 {138} 55 {138} 58 {147} 58 {147} 60 {152} 60 {152}
B - Height to centerline
42 {107} 42 {1067} 42 {1067} 42 {1067} 42 {1067} 42 {1067}
C - Overall length 204 {518} 264 {671} 204 {518} 264 {671} 204 {518} 264 {671}
D - Tank length
192 {468} 252 {640} 192 {468} 252 {640} 192 {468} 252 {640}
E - Overall width 33 {83.8} 33 {83.8} 33 {83.8} 33 {83.8} 33 {83.8} 33 {83.8}
Weight lbs {kg}
Shipping 1800 {816} 1900 {862} 2100 {953} 2200 {998} 2600 {1179} 2755 {1247}
Water requirements 80 gpm @ 60-70 psi {6.1 liters/sec @ 4.8-5.5 bars}; 1.5 in. NPT fitting
Compressed air requirements maximum consumption 5 SCFM @ 80 psi {0.38 liters/sec @ 6.1 bars}
B
A
C
D
E
V caster width
22 in. {56 cm}
ELECTRICAL REQUIREMENTS: Electrical connections are required only if the optional water recirculation package
and heat exchanger is used.See wiring diagrams supplied with the equipment for voltage and amp draws.