Addendum l AD-15
Specifications: Hot Air Dryer (HAD) Blower
A
B
C
Hot Air Dryer mode
l (HAD) 600 800 1000 1600 2400 3200 5000
RECOMMENDED MODEL HTC*
HTC-30B
†
HTC-30B
†
HTC-30A
†
HTC-60A
†
HTC-90A
†
HTC-120A
†
HTC-120A
†
Performance characteristics
Flow rate cfm 300 400 500 800 1200 1600 2500
Disc. pressure @flow rate
inches WC
‡
25 32 30 30 28 30 33
{mm} WC
‡
{635} {813} {762} {762} {711} {762} {838}
Motor Hp kW 5 {3.7} 7.5 {5.6} 7.5 {5.6} 10 {7.5} 15 {11.2} 25 {18.6}
Dimensions inches {cm} and weight lb {kg}
Outlet size selection (OD) 5 5 8 8 8 12
A - Height 42 {107} 42 {107} 42 {107} 42 {107} 42 {107} 42 {107}
B - Width 33 {84} 33 {84} 33 {84} 33 {84} 33 {84} 33 {84}
C - Length 39 {99} 39 {99} 42 {107} 42 {107} 80 {203} 82 {208}
Weight
Installed weight lb {kg}
§
250 {113} 320 {145} 380 {172} 500 {227} 700 {317} 900 {408}
Voltage Full Load Amps
400V/3 phase/50 Hz 9.1 13.2 13.2 16.8 25.2 40.8
460 V/3 phase/60 Hz 7.6 11 11 14 21 34
575 V/3 phase/60 Hz 6.1 9 9 11 17 27
Noise level
with standard soundproofing < 90 dbA @ 5 ft.
SPECIFICATION NOTES:
* For single hopper system.
† The HTC model number reflects the kilowatts of each unit.For example, HTC-60 has a 60 kilowatt heater.
‡
The unit of measure WC is water column.
§
Weights are approximate.
Specifications may change without notice. Consult a Conair representative for the most current information.
TPDM024-0106