Conair 106 Thermostat User Manual


 
Description l 2-3
2
Description
Typical Applications
Carousel Plus “W” Dryer
The HTC process air heater is designed for use with a dehumidifying device
that supplies dry air, such as a central dehumidifying dryer in which the process
heaters (if present) have been disabled, or with a stand alone blower for hot air
drying.
The HTC can be used successfully in applications that require:
Drying temperatures up to 350°F (176.7°C) (250°F [121.1°C] on HAD
models).
The ability to dry multiple materials requiring different drying temperature
setpoints in a central drying system. (Requires separate HTCs / hoppers.)
The ability to easily take a hopper “off-line” for cleaning without shutting
down the entire central drying system.
Hot Air Dryer (HAD)
The HTC process air heater, for use with a hot air dryer such as a Conair model
HAD, connects plant air motivated by a Conair blower assembly to a material dry-
ing hopper.
The HTC for HAD can be used successfully in applications that require:
Drying temperatures up to 250°F (121.1°C).
Non-hygroscopic materials that are in pellet or flake form (not powder).
Open loop drying (not recirculated).
The HTC does not have an integral blower to circulate the hot air, so it can not be
used as a stand-alone material preheater. It must be combined with a Conair
Carousel Plus Series “W” dryer or HAD.