SECTION XIV: REPAIR PARTS
All V8 Series Boiler Repair Parts may be obtained through your local Burnham Wholesale distributor. Should you require as-
sistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair
parts, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408.
b. Air leaking into oil line causing ame out.
c. Defective nozzle causing ame to be erratic.
d. Excessive air ow or draft causing ame to leave
burner head.
e. Excessive back pressure causing ame to be
erratic.
3. Control locks out after Trial For Ignition (TFI).
a. No oil to burner.
b. Shorted electrodes.
c. Nozzle clogged.
d. Air ow too high.
e. Ignitor module defective.
f. CAD cell defective.
g. Oil valve stuck open or closed.
Note: The Safety Monitoring Circuit (SMC) is
designed to provide lockout in the event of a
stuck or welded motor relay.