Burnham V8 Series Boiler User Manual


 
5
TABLE 1A: DIMENSIONAL DATA (SEE FIGURES 1A THRU 1D)
TABLE 1B: RATING DATA
Boiler
Boiler
Model No.
Model No.
Dimensions
Dimensions
See Figures 1A - 1D
See Figures 1A - 1D
Water Content - Gallons
Water Content - Gallons
Heat Transfer
Heat Transfer
Surface Area
Surface Area
- Sq. Ft.
- Sq. Ft.
Approximate
Approximate
Shipping Weight
Shipping Weight
(LB.)
(LB.)
"A"
"A"
"B"
"B"
"C"
"C"
Steam
Steam
Boiler
Boiler
Water
Water
Boiler
Boiler
Steam Boiler
Steam Boiler
V82
V82
12-1/8"
12-1/8"
6-5/8"
6-5/8"
5"
5"
10.0
10.0
450
450
V83
V83
17-1/8"
17-1/8"
9-1/8"
9-1/8"
6"
6"
10.3
10.3
12.8
12.8
15.88
15.88
542
542
V84
V84
22-1/8"
22-1/8"
11-5/8"
11-5/8"
6"
6"
12.4
12.4
15.7
15.7
22.92
22.92
634
634
V85
V85
27-1/8"
27-1/8"
14-1/8"
14-1/8"
7"
7"
14.6
14.6
18.5
18.5
29.96
29.96
726
726
V86
V86
32-1/8"
32-1/8"
16-5/8"
16-5/8"
7"
7"
16.7
16.7
21.4
21.4
37.00
37.00
818
818
V87
V87
37-1/8"
37-1/8"
19-1/8"
19-1/8"
8"
8"
18.8
18.8
24.2
24.2
44.04
44.04
910
910
V88
V88
42-1/8"
42-1/8"
21-5/8"
21-5/8"
8"
8"
20.9
20.9
27.1
27.1
51.08
51.08
1002
1002
V89
V89
47-1/8"
47-1/8"
24-1/8"
24-1/8"
8"
8"
23.0
23.0
30.0
30.0
58.12
58.12
1094
1094
NOTE: 1
NOTE: 1
The V82 Boiler is available as a packaged water boiler only.
The V82 Boiler is available as a packaged water boiler only.
2
2
Maximum working Pressure: Steam: 15 PSI; Water: 30 PSI Shipped From Factory (Std.),
Maximum working Pressure: Steam: 15 PSI; Water: 30 PSI Shipped From Factory (Std.),
40 PSI Optional, 50 PSI Optional
40 PSI Optional, 50 PSI Optional
Boiler
Boiler
Model No.
Model No.
*
*
Burner Capacity
Burner Capacity
I=B=R NET Ratings
I=B=R NET Ratings
Minimum Chmney
Minimum Chmney
Requirements
Requirements
AFUE %
AFUE %
GPH
GPH
MBH
MBH
DOE Heating
DOE Heating
Capacity MBH
Capacity MBH
Water
Water
MBH
MBH
Steam
Steam
MBH
MBH
Steam
Steam
Sq. Ft.
Sq. Ft.
Round
Round
In. Dia.
In. Dia.
Rectangle
Rectangle
In. x In.
In. x In.
Height
Height
Ft.
Ft.
Steam
Steam
Water
Water
V82W
V82W
0.60
0.60
84
84
70
70
61
61
6
6
8 x 8
8 x 8
15
15
82.1
82.1
V83W
V83W
1.05
1.05
147
147
123
123
107
107
6
6
8 x 8
8 x 8
15
15
82.6
82.6
V83S
V83S
V83WM
V83WM
0.75
0.75
105
105
91
91
79
79
68
68
283
283
6
6
8 x 8
8 x 8
15
15
85.1
85.1
86.0
86.0
V84W
V84W
1.35
1.35
189
189
159
159
138
138
7
7
8 x 8
8 x 8
15
15
83.2
83.2
V84S
V84S
V84WM
V84WM
1.05
1.05
147
147
127
127
110
110
95
95
396
396
6
6
8 x 8
8 x 8
15
15
85.3
85.3
86.1
86.1
V85W
V85W
1.65
1.65
231
231
196
196
170
170
7
7
8 x 8
8 x 8
15
15
83.9
83.9
V85S
V85S
V85WM
V85WM
1.35
1.35
189
189
164
164
143
143
123
123
512
512
7
7
8 x 8
8 x 8
15
15
85.4
85.4
86.2
86.2
V86W
V86W
1.90
1.90
266
266
227
227
197
197
8
8
8 x 8
8 x 8
15
15
84.6
84.6
V86S
V86S
V86WM
V86WM
1.65
1.65
231
231
201
201
175
175
151
151
629
629
7
7
8 x 8
8 x 8
15
15
85.7
85.7
86.3
86.3
V87S
V87S
V87W
V87W
2.10
2.10
294
294
252
252
219
219
189
189
787
787
8
8
8 x 8
8 x 8
15
15
84.7
84.7
85.0
85.0
V88S
V88S
2.35
2.35
329
329
266
266
200
200
833
833
8
8
8 x 12
8 x 12
15
15
V88W
V88W
2.35
2.35
329
329
275
275
239
239
8
8
8 x 12
8 x 12
15
15
V89S
V89S
2.60
2.60
364
364
298
298
224
224
933
933
9
9
8 x 12
8 x 12
15
15
V89W
V89W
2.60
2.60
364
364
299
299
260
260
9
9
8 x 12
8 x 12
15
15
*
*
Boiler Model Suf x: S=Steam at standard rate, W=Water, WM=Water at minimum rate
Boiler Model Suf x: S=Steam at standard rate, W=Water, WM=Water at minimum rate