New Buck Corporation 384 Indoor Fireplace User Manual


 
REMOTE CONTROL OR
WALL THERMOSTAT
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do
not force.
6. Wait (5) five minutes to clear out any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the safety information on the reverse side of this label.
If you don’t smell gas, go to the next step.
7. Find Pilot: The pilot is located in front of the rear log and burner on the right hand side of
the appliance. Fully open the manual shutoff valve.
8. Press in and turn knob on gas control counterclockwise to “PILOT” and continue
pressing in the knob for (15) fifteen seconds.
9. With control knob pressed in push down (in) and release the ignitor button (ignitor button is
located on the left hand side of the front of the appliance). This will light the pilot. If
needed, keep repeating this step until pilot lights.
10. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minute,
release the control knob and it will pop back up. Pilot should remain lit. If pilot goes out,
repeat steps 1 through 9.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on the reverse side of this label (page 13).
2. Make sure manual shutoff valve is fully closed. If equipped with thermostat, set to the low-
est setting.
3. Turn off all electrical power to the appliance.
4. Open access door located at bottom of front of the appliance.
5. Push in gas control knob slightly and turn clockwise to the full “OFF” position.
Page 14