Bryant 619E Air Conditioner User Manual


 
SYSTEM CAPACITIES
SYSTEM
TYPE
NOMINAL
SYSTEM
CAPACITY
(Tons)
FAN COIL
TYPE(S)
INDOOR SECTIONS
OUTDOOR
SECTION
538
TOTAL
STANDARD
CFM (AT
HIGH
SPEED)
SYSTEM
NET
COOLING
(Btuh)
SYSTEM
NET
HEATING
(Btuh)*
SEER HSPF*
OUTDOOR
SOUND
RATING
(Decibels)
Ckt Qty
Model
No. 619
Cooling
Only
3
4
High Wall
1 E 009
A 009 286 8,500 10.5 65
1 1 E 012
A 012 358 11,800 11.0 65
1
1
2
1 E 018 C 018 534 17,300 11.5 70
2 1 E 024
C 024 521 22,600 12.0 68
Heat
Pump
3
4
High Wall
1 E 009
D 009 293 9,000 9,000 10.5 6.8 65
1 1 E 012
D 012 350 12,500 12,500 10.5 6.8 65
1
1
2
1 E 018 D 018 502 17,300 16,900 11.5 6.8 70
2 1 E 024
D 024 574 23,200 21,400 11.0 6.8 68
Multi-
Split
2
High Wall A 2 E 018
S 024 1000 23,000 11.0 68
In-Ceiling Cassette A 1 F 024
S 024 1059 23,000 11.0 68
High Wall A 1 E 018
Ceiling Suspended A 1 C 024†
S 024 1034 23,000 11.0 68
High Wall A 1 E 018
4
High Wall
A 2 E 018
S 048 1068 46,000 11.0 72
B 2 E 018
High Wall
A 1 E 024
S 048 1589 46,000 11.0 72
B 2 E 018
High Wall
A 1 E 024
S 048 1042 46,000 11.0 72
B 1 E 024
High Wall A 2 E 018
S 048 2102 46,000 11.0 72High Wall B 1 E 018
Ceiling-Suspended B 1 C 024†
High Wall A 2 E 018
S 048 2127 46,000 11.0 72High Wall B 1 E 018
In-Ceiling Cassette B 1 F 024
High Wall A 2 E 018
S 048 2068 47,000 11.0 72
Ceiling Suspended B 2 C 024†
High Wall A 2 E 018
S 048 2118 46,000 11.0 72
In-Ceiling Cassette B 2 F 024
High Wall A 2 E 018
S 048 2059 46,000 11.0 72Ceiling Suspended B 1 C 024†
In-Ceiling Cassette B 1 F 024
Ceiling Suspended A 2 C 024†
S 048 2034 47,000 11.0 72Ceiling Suspended B 1 C 024†
High Wall B 1 E 018
Ceiling Suspended A 2 C 024†
S 048 2059 47,000 11.0 72In-Ceiling Cassette B 1 F 024
High Wall B 1 E 018
In-Ceiling Cassette A 2 F 024
S 048 2109 46,000 11.0 72In-Ceiling Cassette B 1 F 024
High Wall B 1 E 018
In-Ceiling Cassette A 2 F 024
S 048 2084 46,000 11.0 72Ceiling Suspended B 1 C 024†
High Wall B 1 E 018
High Wall A 2 E 018
S 048 1983 47,000 11.0 72
In-Ceiling Cassette B 1 F 036
High Wall A 2 E 018
S 048 1668 45,800 11.0 72
Ceiling Suspended B 1 C 024
High Wall A 1 E 024
S 048 1521 46,800 11.0 72
In-Ceiling Cassette B 1 F 036
High Wall A 1 E 024
S 048 1559 45,800 11.0 72
Ceiling Suspended B 1 C 024
Ceiling Suspended A 2 C 024†
S 048 1436 46,800 11.0 72
High Wall B 1 E 024
Ceiling Suspended A 1 C 024†
S 048 1121 45,600 11.0 72In-Ceiling Cassette A 1 F 024
High Wall B 1 E 024
LEGEND
Decibels Sound Levels
Ckt Circuit
HSPF Heating Seasonal Performance Factors
SEER Seasonal Energy Efficiency Ratio
*Heat pump systems only.
†Unit must be reconfigured for 1
1
2
ton (18,000 Btuh) operation. Refer to
installation instructions included with the fan coil unit for more details.
NOTES:
1. Rating condition is 80 F db, 67 F wb air entering indoor air section
and 95 F db air entering outdoor air section.
2. Total kW is for total system, including compressor and outdoor and
indoor fans.
3. Ratings are based on 25 ft of interconnecting refrigerant line.
4. All system ratings are based on fan coil units operating at high fan
speed. Consult Specifications tables for airflows at all available fan
speeds.
5