ENGINEER’S SPECIFICATION GUIDE HIGH WALL FAN COIL UNITS (Model 619E)
GENERAL: Furnish and install indoor, wall-mounted, draw-thru,
direct expansion, indoor cooling only or heat pump fan coil unit
to be used without ductwork. Unit shall consist of tangential,
direct-drive fan, fan motor, cooling coil, piping connectors, elec-
trical controls, microprocessor control system, and integral tem-
perature sensing. Unit shall be capable of being used in a
refrigerant circuit with a matching air-cooled outdoor condens-
ing unit.
Nominal unit electrical characteristics shall be
v, single
phase, 60 Hz. The unit shall be capable of satisfactory operation
within voltage limits of
vto v.
Unit shall be capable of providing a constant volume of air at a
specified external static pressure within the unit nominal oper-
ating range.
MAXIMUM DIMENSIONS: Indoor unit width
in.,
depth
in., height inches.
CABINET: Cabinet discharge and inlet grilles shall be attrac-
tively styled, high-impact polystyrene. Cabinet shall be fully in-
sulated for improved thermal and acoustic performance.
FAN SECTION: Fan shall be tangential direct-drive blower type
with air intake at the upper front face of the unit and discharge
at the bottom front. Automatic, motor-driven horizontal air
sweep shall be provided standard.
Air sweep operation shall be user selectable. Vertical direction
may be manually adjusted and horizontal air sweep may be
manually set.
COIL SECTION: Coil shall be copper tube with aluminum fins
and galvanized steel tube sheets. Fins shall be bonded to the
tubes by mechanical expansion. A drip pan under the coil shall
have a drain connection for hose attachment to remove conden-
sate. Condensate pan shall have internal trap and auxiliary drip
pan under coil header.
NOTE: The 009 and 012 units use capillary tubes in the OUT-
DOOR unit for refrigerant control, and the 018,024 units use the
accessory AccuRaterpiston refrigerant metering device in the
INDOOR unit except systems using 538S outdoor units. These
systems have a thermostatic expansion valve in the outdoor
unit.
CONTROLS: Controls shall consist of a microprocessor-based
control system which shall provide the following functions as a
minimum: automatic restart, a timer function, temperature-
sensing controls, evaporator coil freeze protection, wireless in-
frared remote control, auto. stop features, automatic airsweep
control, dehumidification mode, fan-only operation, diagnostics,
a 25-ft indoor-to-outdoor thermistor connection cable, user-
selectable fan speed control, compressor restart time delay, and
condenser high-temperature protection.
ACCESSORIES: Condensate pump.