TYPICAL WIRING SCHEMATIC 538A018,024 COOLING-ONLY SYSTEM
RELAY CHART
Compressor K13
THERMISTOR EQUIVALENCE
Temperature Resistance
°F °C
95 35 6,500
72 22 11,400
32 0 32,500
All thermistors in the 619E systems
are identical to each other
(See Legend and Notes, page 28.)