MODEL NUMBER NOMENCLATURE
1234567891011121314151617
5 8 0 J E 0 6 A 0 7 2 A 1 A 0 A A
____________ ______ ________ ______
Unit Type Packaging
580J = Cooling/Gas Heat RTU A=Standard
Legacy Series w/Puron Refrigerant B=LTL
Voltage Factory Installed Options
E = 460 --- 3 --- 60 0A = None
J = 208/230---1---60
P = 208/230---3---60 Intake/Exhaust Options
T = 575 --- 3 --- 60 A=None
B=Tempeconow/barorelief
Cooling Tons E=Tempeconow/barorelief&CO
2
04 = 3 Ton H = Enthalpy econo w/ baro relief
05 = 4 Ton L = Enthalpy econo w/ baro relief & CO
2
06 = 5 Ton Q = Motorized 2 pos damper
07 = 6 Ton
08 = 7.5 Ton Indoor Fan Options
09 = 8.5 Ton 1 = Standard static option
12 = 10 Ton 2 = Medium static option
14 = 12.5 Ton 3 = High static option
16 = 15 Ton C = High Static Option w/High Efficiency Motor
(Size 16 only)
Refrig. System/Gas Heat Options Coil Options
A = Standard 1---Stage Cooling models/Nat gas heat Models w/Round Tube Plate Fin (RTPF) condenser coil
B = Standard 1---Stage Cooling models/Low NO
x
heat (O utd oo r --- In do or --- H a il G ua r d)
C = Standard 1---Stage Cooling models/SS Gas HX A = Al/Cu ---Al/Cu
D = 2 --- Stage Cooling models 08 --- 16 B = Precoat Al/Cu --- Al/Cu
F = 2 --- Stage Cooling models and S S Gas HX (08 --- 16) C = E --- coat Al/Cu --- Al/Cu
G = 1---Stage Cooling/Al HX w/Perfect Humidity 04---07 D = E --- coat Al/Cu --- E --- coat Al/Cu
H = 1 --- Stage Cooling/Low No
x
Heat w/Perfect Humidity
04---07
E = Cu/C u --- Al/C u
J = 1 --- Stage Cooling/SS Gas HX w/Perfect Humidity
04---07
F = Cu/Cu --- Cu/Cu
K = 2---Stage Cooling/Al Gas HX w/Perfect Humidity 08-14 M = Al/Cu --- Al/Cu --- Louvered Hail guard s
M = 2---Stage Cool/SS Gas HX w/Perfect Humidity 08-14 N = Precoat Al/Cu --- Al/Cu --- L ouvered Hail Guard s
P = E coat Al/Cu --- Al/Cu --- Lou vered Hail Guards
Heat Level Input Q = E coat Al/Cu --- E coat Al/Cu --- L ouvered Hail Guard s
Standard/Stainless Steel R = Cu/ Cu --- Al/C u --- Lou vered Hail Guards
072 = 72,000 S = Cu/C u --- C u/Cu --- Louvered Hail Guards
115 = 115,000 Models w/All aluminum, Novation condenser coils
125 = 125,000 (O utd oo r --- In do or --- H a il G ua r d)
150 = 150,000 G = Al/Al --- Al/ Cu
180 = 180,000 H = Al/Al --- Cu/Cu
224 = 224,000 J = Al/Al --- E coat Al/Cu
240 = 240,000 K = E coat Al/Al --- Al/ Cu
250 = 250,000 L=EcoatAl/Al---EcoatAl/Cu
350 = 350,000 T = Al/Al --- Al/Cu --- Lou vered Hail Guards
Low NO
x
U = Al/Al --- Cu/ Cu, Louvered Hail Guards
060 = 60,000 V = Al /Al --- E coat Al/Cu, Louvered Hail Guards
090 = 90,000 W = E coat Al/Al --- Al/ Cu, Louvered Hail Guards
120 = 120,000 X = E coat Al /Al --- E coat Al/Cu, Louvered Hail Guards