Bryant 580J Air Conditioner User Manual


 
3
FEAT URES AND BENEFITS
S Single cool ing stage models are available from 3 -- 10 ton.
S Two cooling stage models are available from 7.5 -- 15 ton.
S SEER up to 13. 0.
S EER’s up to 11.1.
S IEER’s up to 11.8.
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement j obs.
S Utility connections are the same because 3 -- 12.5 t on units fit on existing Bryant rooftop curbs. This saves time and
money on replacement jobs.
S Standardized components and layout. Standardized component s and controls make service and stocking parts easier.
S Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.
S Field conve rtible airflow (3 -- 15 ton). Being able to convert a unit from vertical ai rflow to horizontal makes it easy to
overcome job site complic ations. 15 ton models require a simple supply duct cover to field convert from factory vertical
to horizontal.
S Easy--adjust, belt--drive motor availabl e. Bryant provide s a factory solution for most points in the fan performance table.
S Provisions for bottom or side condensate drain.
S Capable of thru--the--base or thru--the--curb gas li ne routing.
S Single--point gas / electrical connection.
S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.
S Standardized controls & control box layout. Standardized components & controls make stocking parts & service easier.
S Tool--less filter access door.
S Clean, easy to use control box.
S Color--coded wiring.
S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting e asy.
S Singl e, central terminal board for test and wiring connections.
S Fast--access, handled, panels for easy access on normally accessed service panels.
S “No--strip” screw system guides screws int o the panel & captures them ti ghtly without stripping the screw, the panel, or
the unit.
S Exclusive, newly --design indoor refrigerant header for easier maintenance and replacement.
S Mechanical cooling (115_Fto40_For46_Cto4_C) standard on all models. Winter Start Kit allows cooling operation
downto25_F(--4_C) and Motor Master to --20_F(--29_C).
S High efficiency, gas heat with induced--draft flue exhaust design (3 -- 15 tons).
S Induce draft motor ensures no flue gas can escape into the indoor air stream.
S Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be
periodically, manually drained. This saves labor and maintenance expense.
S 2-- in (51mm) disposable filters on all units.
S Refrigerant filter -- drier on each circuit.
S Each circuit is protected with a high and low pressure switch.
S Many factory--installed options ranging from air manage ment economizers, 2 position dampers, plus convenience
outlets, disconnect switch and smoke detectors.
S
Standard Parts Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr. parts.
S Factory--instal led Perfect Humidity system on 3 -- 12.5 ton model s, includes MotorMaster I controller.
580J