Bradford-White Corp TG-180I-N(X) Water Heater User Manual


 
57
INITIAL OPERATION AND TESTING OF CONTROLS (INSTALLER ONLY)
1. Turn on power to the water heater and fully open a hot water tap.
2. Check the operation of the water heater. Check the operation of the remote temperature
control(s). Check the operation of the power failure protection system (drain solenoids).
3. Explain the proper operation of the new Bradford White EverHot
water heater to the end user.
Troubleshooting – Electrical
There are a number of (live) tests that are required when fault finding this product. Extreme care should
be used at all times to avoid contact with energized components inside the water heater. Only trained
and qualified service technicians should attempt to repair this product. Before checking for resistance
readings, disconnect the power source to the unit and isolate the item from the circuit (unplug it).
Table 15. (SV1, SV2, SV3, and POV) Gas Valve and Modulating Solenoids (Set Meter Above 2k).
Wire Color Voltage Resistance
Connector
No.
Pin
Nos.
(Main) Pink-Black 11-13 VDC 36.8-44.8 ohms H5 6-7
(SV1) Black-Yellow 11-13 VDC 36.8-44.8 ohms H6 5-6
(SV2) Black-Blue 11-13 VDC 36.8-44.8 ohms H7 4-6
(SV3) Black-Brown 11-13 VDC 36.8-44.8 ohms H8 3-6
(POV) Pink-Pink 2-15 VDC 67-81 ohms H3 9-10
Table 16. (M) Water Flow Control Device Servo or Geared Motor.
Wire Color Voltage Resistance
Connector
No.
Pin
Nos.
Red-Blue 11-13 VDC 22-28 ohms F7 9-10
Grey-Brown 4-6 VDC n/a F7 5-7
Grey-Yellow n/a n/a F7 5-8
Note: The grey wire listed above turns to black at F connector on the PCB.
Table 17. (QS) Water Flow Sensor.
Wire Color Voltage Resistance
Connector
No.
Pin
Nos.
Black-Red 11-13 VDC 5.5-6.2k ohms F2 1-3
Yellow-Black 4-7 VDC 1-1.4 Mega ohms F2 2-3
Table 18. By-pass Flow Control (By-pass Servo Model Only).
Wire Color Voltage Resistance
Connector
No.
Pin
Nos.
Brown-White
2-6 VDC (unit
in operating
mode)
15-35 ohms
G1 1-5
Orange-White G1 2-5
Yellow-White G1 3-5
Red-White -
Ground
G1 4-5
Table 19. (IG) Ignition System.
Wire Color Voltage Resistance
Connector
No.
Pin
Nos.
Grey-Grey 90-110 VAC n/a C1 1-2