Bosch Appliances CC880 Home Security System User Manual


 
CC880/LP880, SC8016 | Operators Guide | 5.0 Disarming the System EN | 9
Bosch Security Systems | 6/04 | 920036O.OG.162
How to Arm the System in STAY Mode 2
Hold down the [0] button until two beeps are heard.
The STAY indicator displays and exit time starts
counting.
Any zones programmed to be automatically isolated
in STAY Mode 2 flash until exit time expires. At the
end of exit time, all zones selected to be
automatically isolated turn off and the codepad gives
one short beep.
4.5 Programming STAY Mode 2 Zones
Programming zones to be automatically isolated in
STAY Mode 2 are only carried out if you have a
master code.
How to Program STAY Mode 2 Zones
1. Enter your four character master code, followed
by [8] and the [#] button (for example,
[2 5 8 0 8 #]). Three beeps are heard and the
STAY indicator flashes.
2. Enter the zone number to be automatically
isolated, followed by the [*] button (for example,
[1 *] = Zone 1, [2 *] = Zone 2).
The selected zone flashes. If you make a mistake,
enter the same zone number followed by the [#]
button to clear the incorrect zone.
To select additional zones to be automatically
isolated in STAY Mode 2, repeat Step 2 as many
times as required.
3. To exit this mode, press the [#] button when you
have selected all zones to be automatically
isolated in STAY Mode 2. Two beeps are heard
and the STAY and AWAY indicators turn off.
5.0 Disarming the System
When you enter the premises after the system is
armed in AWAY Mode, or if you armed the system
in STAY Mode 1 or STAY Mode 2, you must disarm
the system before entry time expires to disable
detection devices that activate an alarm.
If there was an alarm condition prior to disarming
the system, a flashing zone indicator displays,
indicating a previous alarm on that zone.
How to Disarm the System
Enter your user code followed by the [#] button (for
example, [2 5 8 0 #]). Two beeps are heard.
6.0 Adding User Codes
Only the master code holder can add or change
other system user codes, including two auxiliary
codes and the master code. The master code is
factory default is User 1; however, multiple user
codes can be assigned to be a master code. Up to 32
user codes can be programmed to operate the
system. User code 33 and user code 34 are auxiliary
codes only.
How to Add a User Code
1. Enter your four character master code, followed
by [1] and the [#] button (for example,
[2 5 8 0 1 #]).
Three beeps are heard and the STAY and
AWAY indicators flash.
2. Enter the user code number (1 to 34), followed
by the [#] button (for example, [2 #] = User 2,
[3 3 #] = Auxiliary Code 1). Two beeps are
heard and the selected user number displays on
the codepad indicators.
3. Enter the digits (up to seven digits) required for
the new code followed by the [#] button (for
example, for user code 5768, enter [5 7 6 8 #]).
Two beeps are heard and the STAY and AWAY
indicators turn off.
To add or change other user codes, repeat this
procedure as many times as required.
7.0 Deleting User Codes
Only the master code holder can delete other system
user codes and auxiliary code 1 and 2.
How to Delete a User Code
1. Enter your four character master code, followed
by [1] and the [#] button (for example,
[2 5 8 0 1 #]).
Three beeps are heard and the STAY and
AWAY indicators flash.
2. Enter the user code number (1 to 34), followed
by the [#] button (for example, [2 #] = User 2,
[3 3 #] = Auxiliary Code 1). Two beeps are
heard and the selected user number displays on
the codepad indicators.
3. Press the [*] button to delete the selected user
code.
Two beeps are heard and the STAY and AWAY
indicators turn off.
To delete other user codes, repeat this procedure
as many times as required.