Bosch Appliances CC880 Home Security System User Manual


 
CC880/LP880, SC8016 | Operators Guide | 4.0 Arming the System EN | 8
Bosch Security Systems | 6/04 | 920036O.OG.162
4.1 Forced Arming
Forced arming arms the system when a zone is not
sealed. If the system does not arm and a long beep is
heard, forced arming is not permitted. In this case,
you must ensure that all zones are sealed or manually
isolated before you can arm the system.
4.2 Arming in AWAY Mode
When you leave your premises and require all zones
to be in a ready state to detect intrusion, you arm the
system in AWAY Mode.
There are two different methods for arming the
system in AWAY Mode. Method one is standard and
always operates. Method two is optional and can be
disabled by your installer if you do not want to use
single button arming.
Table 9: How to Arm the System in AWAY Mode
Method One
Enter your user code followed by the
[#] button (for example, [2 5 8 0 #]).
Two beeps are heard and the AWAY
indicator displays. Exit time starts
counting.
Method Two
Hold down the [#] button until two
beeps are heard.
The AWAY indicator displays and
exit time starts counting.
4.3 Arming in STAY Mode 1
STAY Mode 1 is only used when the perimeter and
unused areas of the premises need to be armed to
detect an intruder entering the premises. At the same
time, this mode allows you to move freely within an
area that is automatically isolated.
Only your security company can program zones
automatically isolated in STAY Mode 1.
There are two different methods for arming the
system in STAY Mode 1. Method one is standard
and always operates. Method two is optional and can
be disabled by your installer if you do not want to
use single button arming.
Entry Guard Timer For STAY Mode 1
When arming the system in STAY Mode 1, an
optional entry timer called Entry Guard Timer For
STAY Mode 1 is used. Use this entry timer to delay
the sirens if a zone is not automatically isolated and
triggered an alarm condition. Entry Guard Timer For
STAY Mode 1 is the delay time used for all zones
except 24-hr. zones when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode 1 is
programmed and a zone not automatically isolated is
triggered, the codepad beeps twice a second until the
entry timer expires or the system is disarmed. If the
alarm condition is not reset by entering your user
code followed by the [#] button (such as, [2 5 8 0 #])
before the entry timer expires, the sirens activate into
alarm. Only your installer can program this feature.
Table 10: How to Arm the System in STAY Mode 1
Method One
Enter your user code followed by the [*]
button (for example, [2 5 8 0 *]).
Two beeps are heard and the STAY
indicator displays. Exit time starts counting.
Any zones programmed to be automatically
isolated in STAY Mode 1 flash until exit time
expires. At the end of exit time, all zones
selected to be automatically isolated turn off
and the codepad gives one short beep.
Method Two
Hold down the [*] button until two beeps are
heard.
The STAY indicator displays and exit time
starts counting.
Any zones programmed to be automatically
isolated in STAY Mode 1 flash until exit time
expires. At the end of exit time, the zone
indicators turn off and the codepad gives
one short beep.
4.4 Arming in STAY Mode 2
STAY Mode 2 is only used when the perimeter and
unused areas of the premises need to be armed to
detect an intruder from entering the premises. At the
same time, this mode allows you to move freely
within an area that is automatically isolated. Any
Master Code user can program zones to be
automatically isolated in STAY Mode 2.
Entry Guard Timer For STAY Mode 2
When arming the system in STAY Mode 2, an
optional entry timer called Entry Guard Timer for
STAY Mode 2 can be used. Use this entry timer to
delay the sirens if a zone is not automatically isolated
and triggered into alarm condition. Entry Guard
Timer for STAY Mode 2 is the delay time used for
all zones except 24-hr. zones when the system is
armed in STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode 2 is
programmed and a zone, not automatically isolated,
triggers, the codepad beeps twice a second until the
entry timer expires or the system disarms. If the
alarm condition is not reset by entering your user
code followed by the [#] button (for example,
[2 5 8 0 #]) before the entry timer expires, the sirens
activate into alarm. Only your installer can program
this option.